Manuals
/
Honeywell
/
Household Appliance
/
Home Security System
Honeywell
2-Partitioned Security System, VISTA-40
manual
$0&29,67$, N7001PRV5 5/04 Rev a
Models:
2-Partitioned Security System
VISTA-40
1
1
36
36
Download
36 pages
10.09 Kb
1
2
3
4
5
6
7
8
<
>
Character Ascii Chart
Alarm
Select Default Screen mode
Enable OPEN/CLOSE Report for
Programming With #93 Menu Mode
Page 1
Image 1
$'(0&29,67$
3DUWLWLRQHG6HFXULW\6\VWHP
3URJUDPPLQJ*XLGH
N7001PRV5 5/04 Rev A
Page 2
Page 1
Image 1
Page 2
Contents
N7001PRV5 5/04 Rev a
$0&29,67$
Table of Contents
Recommended Programming Procedure
Field Group
Program Field Index
Field Group
VISTA-40 Programming Form
OPEN/CLOSE Report for Keyswitch
Enable OPEN/CLOSE Report for
54 *57 Alarm Report Codes & ID Digits for Zones
59 *62 Alarm Report Codes & ID Digits for Zones
2nd Page Programming Fields press *94
Fields 1*28 1*31 are not applicable for UL installations
3rd Page Programming Fields press *94
Partition # Program Fields
Partition-Specific Fields
1st Page Fields
2nd Page Fields
Programming With #93 Menu Mode
SET to CONFIRM? = YES
Zone Programming
Enter Zone no = Quit
Zone Type PERIMETER03
Input S/N AXXX-XXXX
Input Type
Input S/N
Xmit to Confirm Press to Skip
Series Transmitters Loop Designations
Program field 200 Number of Partitions
Expert Mode Zone Programming
Enter Zone no
SET to CONFIRM?
From Template
Input S/N XXX-XXXX
5804BD
Wireless Key Default Templates 5804
Template Loop Function
Zone Type Template Loop Function
Zone Descriptors Select Zone Descriptor mode
Zone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP?
Alpha Descriptors Programming
Exit Edit MODE?
Select Custom Word Mode
Select Default Screen mode
Accept the word
Select the next word
Follow the same procedure as for custom words
Type the word using one of two methods as follows
Enter the custom word number 01-20 you want to create
Save the word by pressing
Alpha Descriptor Vocabulary
Character Ascii Chart
Alpha Keypad
Device Programming
RF Expander
VIP Module
Fault
Alarm
Relay Programming
Trouble
Choices for Start/Stop Zone Types and System Operations
Relay Output Devices Programming
Enter Relay #
Relay Action No Response Start Event Not Used
Start Partn ANY Partition
Zone List Programming
Relay Type Plex ECP Address Module RELAY# House Code
Unit Code
Relay Voice Descriptors
Custom Word no =QUIT Enter Index #
Custom Word Substitutes for VIP Module Annunciation
Descriptor Prim Partition # Char max Sub. #
System Layout Worksheets
Defaults
Access Codes & User Definitions for Partitions 1
Zone Definition for Zones
Zone Definition for Zones
Zone Definition for Zones
Zone Definitions for System Zones 70, 88 89, 90, 91
Zone Definitions for Keypad Panic Zones 95, 96
Zone Types
Input Types
Choices for System Operation are
Relay Outputs Worksheets
Page
Ground
Ademco VISTA-40 Summary of Connections
Eileen Way, Syosset, New York
Top
Page
Image
Contents