Relay Output Devices Programming
From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt. Press [0] (NO) to each menu option until the "RELAY PROG?" prompt appears. Press [1] (YES).
While in this mode, press [✱] to advance to next screen. Press [#] to back up to the previous screen.
PROMPTEXPLANATION
ENTER RELAY #
(00=QUIT) 01
02 A EV ZL P STT 0 0 00 0
02A ZL ZT P STOP 0 00 00 0
| 02 | RELAY ACTION |
|
| NO RESPONSE | 0 | |
| |||
|
|
|
|
|
|
|
|
| 02 | START EVENT |
|
| NOT USED | 0 | |
|
Enter the relay (output device) identification number
Press [✱] to continue.
Press [✱] to continue.
The keypad displays a summary STOP screen.
Press [✱] to continue.
The Relay Action is the way in which the relay will respond when activated by the "start" event. Enter the desired action for this relay as follows:
0=not used; 1=close for 2 secs.; 2=stay closed; 3=pulse on/off
A relay may be activated by an Event/Zone List combination, and/or by a Zone Type/System Operation. For an Event/Zone List combination, enter the event code as follows:
0=not used; 1=alarm; 2=fault; 3=trouble
If you are not using a Zone List to activate the relay, enter 0. Press [✱] to continue.
| 02 | START: ZN LIST |
|
|
|
| 0 |
|
|
| |
|
|
|
|
|
|
|
|
| 02 | START: ZN TYPE |
|
| NO RESPONSE | 00 | |
|
A zone list is a set of zones that can be used to initiate the start or stop relay action. If a zone list is being used to start this relay action, enter the zone list number,
A Zone Type/System Operation can be used instead of or in addition to an Event/Zone List combination or a specific zone to start the relay action. If a Zone Type/System Operation is being used, enter the
Press [✱] to continue.
Choices for Start/Stop Zone Types and System Operations:
00 | = No Response (Not Used) |
| 23 | = No Alarm Response |
01 | = Entry/Exit #1 | 31 | = End of Exit Time | |
02 | = Entry/exit #2 | 32 | = Start of Entry Time | |
03 | = Perimeter | 33 | = Any Burglary Alarm | |
04 | = Interior Follower | 34 | = Code + [#] + 71 Key Entry | |
05 | = Trouble Day/Alarm Night | 35 | = Code + [#] + 72 Key Entry | |
06 | = |
|
| = At Bell Timeout ** |
36 | ||||
07 | = | 37 | = 2 Times Bell Timeout ** | |
08 | = | 38 | = Chime | |
09 | = Fire Alarm or Trouble | 39 | = Fire Alarm | |
10 | = Interior w/Delay | 40 | = Bypassing | |
20 | = | 31 | = End of Exit Time | |
21 | = | 41 | = AC Power Fail | |
22 | = Disarming (Code + Off) |
| 42 | = System Battery Low |
*Stop condition only
**Or at disarming, whichever occurs earlier
43 = Communication failure
44 = RF Low Battery
45 = Polling Loop Failure
51 = RF Receiver Failure
52 = Kissoff
54 = Fire Zone Reset
55 = Disarm + 1 Minute
56 = XX Minutes (enter XX in field 1*74) * 57 = YY Seconds (enter YY in field 1*75) * 58 = Duress
60 = Audio Alarm Verification (must be selected for both START and STOP operation)
If you are using options 56 and/or 57 (usually as the STOP Zone Type), you must program data fields 1*74 and 1*75 for the respective relay timeouts for minutes and seconds.
– 23 –