Honeywell VISTA-40 manual Promptexplanation, Wireless Key Default Templates, 5804BD

Models: 2-Partitioned Security System VISTA-40

1 36
Download 36 pages 10.09 Kb
Page 16
Image 16
Wireless Key Default Templates

PROMPTEXPLANATION

PARTITION

1

ENTER ZONE NO

00 = QUIT

24

Example of zone number suggested by the system. This indicates that zones 24, 25, 26, and 27 are available.

24 INPUT S/N

L

AXXX-XXXX

1

 

 

XMIT TO CONFIRM

PRESS TO SKIP

Entd A022-4063

Rcvd A022-4064

Enter partition number for wireless key.

Press [] to continue.

The system searches for the highest available, consecutive 4-zone group (the four zones required for the 5804 and 5804BD), and displays the lowest zone number of the group.

If you want to start at a different zone number, enter the zone desired and press [].

If that zone number is displayed, the system has the required number of consecutive zones available, beginning with the zone you entered. If not, the system again displays a suggested zone that can be used.

If the required number of consecutive zones is not available at all, the system will display “00.” Press [] to accept.

To enter the serial number:

Press and release a button on the wireless key.

OR

Manually enter the 7-digit serial number printed on the device’s label. Press [] to accept serial number. The system checks for a duplicate.

If a duplicate exists, a long error beep will sound and the serial number reverts back to all “X”s allowing you to re-enter the serial number.

Use the [A] key to move forward within the screen, and the [B] key to back up.

If you entered YES previously at the SET TO CONFIRM prompt (see first prompt following entry into the Expert Programming Mode), the display on the left appears.

To confirm, activate the button on the wireless key that corresponds to this zone.

If the serial number transmitted does not match the serial number entered, a display similar to the one at the left appears.

If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key and then enter the correct serial number.

Activate the button on the wireless key again after re-entering the serial number.

ENTER ZONE NO

 

00 = QUIT

28

If the serial number transmitted matches the serial number entered, the system will beep 3 times and revert to the "Start Zone No." prompt and will show the lowest numbered zone of the next available 4-zone group (4 consecutive zones) that is available for programming.

After all the wireless keys have been entered, enter 00 for the zone number to quit.

After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information (zone number, zone type, etc.) relevant to that device.

Wireless Key Default Templates

5804

Template 1

Template 2

Template 3

Loop Function

1No Response

2Disarming

3Arm AWAY

4No Response

Loop Function

1No Response

2Disarming

3Arm AWAY

4Arm STAY

Loop Function

124-Hour Panic

2Disarming

3Arm AWAY

4Arm STAY

 

5804BD

Zone Type

Template 4

23

 

22

 

21

 

23

 

Zone Type

Template 5

23

 

22

 

21

 

20

 

Zone Type

Template 6

07

 

22

 

21

20

Loop

1

2

3

4

Loop

1

2

3

4

Loop

1

2

3

4

Function

No Response

No Response

Arm AWAY

Disarming

Function

No Response

Arm STAY

Arm AWAY

Disarming

Function

24-Hour Panic

Arm STAY

Arm AWAY

Disarming

Zone Type

23

23

21

22

Zone Type

23

20

21

22

Zone Type

07

20

21

22

– 16 –

Page 16
Image 16
Honeywell VISTA-40, 2-Partitioned Security System manual Promptexplanation, Wireless Key Default Templates, 5804BD