Programming With #93 Menu Mode

Programming With #93 Menu Mode

NOTE: The following field should be preset before beginning: 2*00 Number of Partitions. In addition, receivers should be programmed via Device programming.

After programming all system related programming fields in the usual way, press #93 while still in programming mode to display the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 will display the next choice in sequence.

UL

For UL installations, verify that the audio alarm verification feature is disabled.

 

#93 MENU MODE KEY COMMANDS

The following is a list of commands used while in the menu mode.

#93

Enters Menu mode

[4]

Serves as ENTER key. Press to have keypad accept entry.

[#]Backs up to previous screen.

0 Press to answer NO

1 Press to answer YES

01-09 All data entries are either 1-digit or 2-digit entries.

00 Exits menu mode, back into field programming mode, when entered at the first question for each category.

Menu selections are as follows:

PROMPTEXPLANATION

ZONE PROG?

 

1 = YES 0 = NO

0

For programming the following:

Zone Number

Zone Response Type

Partition Number for Zone

Dialer report code for zone

Input Device Type for zone (whether RF, polling loop, etc.)

Enrolling serial numbers of 5800 Series transmitters & serial polling loop devices into the system.

 

EXPERT MODE?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

ALPHA PROG?

 

 

1 = YES

0 = NO

0

 

Same as Zone Programming except:

Done with a minimum number of keystrokes.

Can program wireless keys using pre-defined templates.

For entering alpha descriptors for the following:

Zone Descriptors

Installer's Message

Custom Words

Partition Descriptors

Relay Descriptors

DEVICE PROG?

 

1 = YES 0 = NO

0

For defining the following device characteristics for addressable devices, including keypads, RF receivers (5881), output relay modules (4204), and 4285/4286 VIP Module:

Device Address

Device Type

Keypad Options (incl. partition assignment)

RF House ID

 

RELAY PROG?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

RLY VOICE DESCR?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

CUSTOM INDEX ?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

For defining relay functions.

For entering voice descriptors for relays to be used with the 4285/4286 VIP Module.

For creating custom word substitutes for VIP Module annunciation.