Honeywell VISTA-40, 2-Partitioned Security System manual Promptexplanation, Zone List Programming

Models: 2-Partitioned Security System VISTA-40

1 36
Download 36 pages 10.09 Kb
Page 24
Image 24
Zone List Programming

PROMPTEXPLANATION

02 START: PARTN

 

ANY PARTITION

0

If the starting event will be limited to occurring on a specific partition, enter the partition number (1-2) in which the start event will occur. Enter 0 for any partition.

Press [] to continue.

Do not use a zone programmed with an RF Button (Input Type BR) to STOP a relay. The system will not de- activate the relay.

PROMPTEXPLANATION

 

02

STOP: ZN LIST

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

 

 

02

STOP: ZN TYPE

 

 

NO RESPONSE

00

 

 

 

 

 

 

 

 

 

 

02

STOP: PARTN

 

 

ANY PARTITION

0

 

 

 

 

 

 

 

 

 

 

02

RESTRICTION

 

 

1=YES 0=NO

0

 

 

 

 

 

 

 

 

 

 

02

RELAY TYPE

 

 

V-PLEX

0

 

 

 

 

 

 

 

 

 

 

02

ECP ADDRESS

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

 

02 MODULE RELAY#

 

 

0

 

 

 

 

 

 

 

02 HOUSE CODE

 

 

A

00

 

If a zone list is being used to stop this relay action, enter the zone list number, 1-4. The restore of a zone on the zone list stops the relay. If a zone list is not being used, enter 0.

Press [] to continue.

If a Zone Type/System Operation is being used to stop the relay action, enter the 2-digit code listed in the Choices for Start/Stop System Operation chart.

Press [] to continue.

This is the partition to which the stop condition will be limited. Enter 0 for any partition. Enter 1-2for specific partition number.

Press [] to continue.

The system may have some devices that are not intended to be under end user control, such as relays activating fire doors or machinery. Enter 1 if the end user will be restricted from accessing this relay. Press [] to continue.

Enter 1 for (ECP) relay modules (4204). Enter 2 for X-10 devices.

Press [] to continue.

If you selected 1 (4204), enter the actual module’s address (01-15)as set by its DIP switches. Up to 2 modules can be installed in a system.

Press [] to continue.

For 4204 Relay Outputs, enter the specific relay number on that module (1-4).

Press [] to continue.

The keypad will display the Start and Stop summary screens again.

Press [] to continue.

If you selected 2 for X-10 devices, enter the numerical equivalent of the House Code of the device, as follows:

A=00

D=03

G=06

J=09

M=12

P=15

B=01

E=04

H=07

K=10

N=13

 

C=02

F=05

I=08

L=11

O=14

 

 

 

 

 

 

 

02 UNIT CODE

00

Enter the numerical unit code of the X-10 device (00-15). Press [] to continue.

The keypad displays the Start and Stop summary screens again. Press [] to continue.

When all relays have been programmed, enter 00 at the "ENTER RELAY NO." prompt.

If you are defining a zone list, continue to the next section. If not, enter 00 + [] at the next two prompts. You will then be asked "Quit Menu Mode?" Enter 1 for "Yes," 0 for "No." Then enter []99 to exit programming completely.

Zone List Programming

After all relays have been programmed, upon entering 00 at the "ENTER RELAY NO." prompt, you are asked to enter a zone list. If a zone list number was used to start or stop a relay, you must define the zones belonging to that list as follows:

PROMPTEXPLANATION

ENTER Zn LIST ?

00=QUIT00

Enter the zone list number 01-04. Enter 00 to quit.

– 24 –

Page 24
Image 24
Honeywell VISTA-40, 2-Partitioned Security System manual Promptexplanation, Zone List Programming