Honeywell 2-Partitioned Security System manual ADEMCO VISTA-40, Summary Of Connections

Models: 2-Partitioned Security System VISTA-40

1 36
Download 36 pages 10.09 Kb
Page 35
Image 35
– 35 –

– 35 –

 

WARNING: OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED

 

 

 

 

 

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM.

 

NOTES: 1.

Zone 1 may be selected for EOLR supervised

 

4. Zone 8 supports 2-wire latching type glass break detectors.

J7 Header

 

 

J8 Header

 

 

 

 

 

 

 

 

 

 

 

MAKE CONNECTIONS USING

 

 

 

or normally closed (no EOLR) operation via

 

 

See Installation and Setup Guide

for recommended type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Not Used

 

1.

In 2 (Printer DTR)

 

Optional programming:

 

 

 

No. 4142TR CABLE

 

 

 

cut jumper. (Cut red jumper for normally closed

 

 

and maximum number of detectors supported.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Ground-

 

 

2.

Ground

 

 

 

Out 1: Open/close or keypad-like sounding

 

 

 

operation. Do not cut for Fire Usage). Zones 2-8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue

 

 

5. Cut blue jumper to disable supervision of alarm sounder output.

3. Out 1 (Ground Start)

3. In 3 (1361X10 sync)

 

Out 2: Armed LED

 

 

 

 

 

 

may be selected for either operation via program

 

 

 

 

 

 

J8

Jumper

 

 

4. Ground-

 

 

4. In 4 (1361X10 sync)

 

Out 4: Ready LED

 

 

 

 

(note 5)

 

field *41.

 

 

 

 

 

 

 

Leave jumper intact to supervise output. (See Installation and

5. Out

2 (fire)

 

5.

Ground

 

 

 

Ratings for Out 1-4:

 

 

 

 

 

 

 

2. Zone 1 supports 2-wire smoke detectors.

 

 

 

Setup Guide for Programming and Wiring Instructions).

 

6. Ground-

 

 

6. Out 5 (1361X10 data)

Active: 10VDC-13.8VDC through 5k OHMS

1 2 3 4 5 6 7 8 9

 

 

 

 

 

 

 

 

 

 

 

 

 

7. Out

3 (burg/aud. panic) 7.

Out 6 (Printer RXD)

 

Not

Active: 100 OHMS to ground.

 

 

 

 

 

See Installation and Setup Guide for recommended

 

 

 

 

 

 

 

 

 

 

 

 

 

BATTERY

 

 

 

 

 

 

 

 

 

 

8. Ground

 

 

8. Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

type and maximum number of detectors supported.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9. Out 4 (silent panic/

9.

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

TABS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

duress)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(+)

3. Zone 7 may be used for remote keyswitch

 

 

 

 

 

 

 

 

 

 

 

(Refer to Installation Instructions for information concerning Direct Wire

 

 

 

Connect to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8 9

RED

 

arming/disarming. See Installation and Setup Guide

 

 

 

Red Jumper (note 1)

 

 

 

 

 

Downloading and printer connections using the 4100SM Serial Module.)

 

 

12VDC, 4AH

 

for wiring instructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or 12VDC, 7AH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EARTH GROUND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GEL CELL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE 2 ZONE 3

ZONE 4 ZONE 5

 

ZONE 6 ZONE 7

 

ZONE 8 ZONE 9

 

 

 

 

 

 

 

 

 

Connect to good earth

 

 

1

2

3

4

5

6

7

 

8

9

10

11

12

13

14

15

16

17

18

19

20

 

21

22

23

24

25

26

27

28

 

29

30

ground to maintain im-

BATTERY

(-)

 

 

 

 

 

 

 

 

munity to transients.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHARGING

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

-

 

 

 

 

 

 

See Instructions for

 

 

 

 

 

 

 

 

 

 

 

 

ZONE 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(BROWN)

(GRAY) (GREEN)

 

 

 

proper grounding.

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RED)

 

See

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13.7VDC

 

 

 

 

 

 

 

 

 

in

out

 

 

+

-

+

 

 

 

+

 

-

+

 

LATCHINGTYPEGLASS DETECTORBREAK LOOP

 

 

 

 

 

RING

TIP

RING

 

DOC LOAD NO.: 5

 

16.5VAC, 40VA

 

 

 

CONNECTIONNO

 

 

 

 

Data

Data

 

SMOKEWIRE-2 DETECTORLOOP NO/NCsupportsBurgcontacts)

2k EOLR

2k EOLR

 

2k EOLR

2k EOLR

ProgrammableResponse

(Fast/Normal)Loop

 

POLLINGLOOP

 

TIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS EQUIPMENT SHOULD BE INSTALLED

Installation

Connect to

 

 

 

 

 

 

+

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: TO PREVENT

Instructions for

24hr. 120VAC,

 

 

 

 

 

 

 

 

 

 

 

N.C.

 

N.C.

 

 

 

N.C.

 

N.C.

 

 

 

 

 

 

 

Handset

Incoming

required

60 Hz Outlet

 

 

 

 

 

 

Red

Blk

 

Grn

Yel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phone Line

RISK OF ELECTRICAL

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace

 

 

 

 

 

 

 

REMOTE KEYPAD/DEVICES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Telephone connections

SHOCK, DISCONNECT

 

 

 

 

 

 

 

(Addressable keypads only)

 

 

N.O.

 

N.O.

 

 

 

N.O.

 

N.O.

 

 

 

 

 

 

 

using Ademco No. 620

TELCO JACK BEFORE

every

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 years

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RJ31X direct connect

SERVICING THIS PANEL.

 

 

 

 

 

 

 

See Installation Instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cord.

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for maximum number of keypads

 

 

 

 

 

 

 

 

 

 

 

 

 

+

-

+

 

 

 

 

 

 

 

 

 

 

 

ADEMCO No.1361

 

 

 

 

 

 

and for maximum wire run length.

 

(Also

(note 1)

(note 1)

 

 

(note 1)

 

(note 1,3)

 

 

 

 

 

IN ACCORDANCE WITH THE NATIONAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(IN CANADA USE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

-

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. 1361CN)

 

 

 

 

+

 

-

 

 

 

 

+

-

Fire

 

 

 

 

 

 

GLASS

 

 

 

 

4208U

 

FIRE PROTECTION ASSOCIATION'S

 

 

 

BELL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STANDARD 72 (NATIONAL FIRE

 

OR 1361X10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Usage

 

 

 

 

 

 

 

 

BREAK

 

 

 

 

 

 

 

 

IF X-10 DEVICES

 

 

+

-

 

 

 

 

 

 

 

 

 

 

 

 

N.C.

 

N.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

PROTECTION ASSOC., BATTERYMARCH

 

WILL BE USED

 

 

AUXILARY POWER OUTPUT

 

SMOKE

 

 

 

 

 

 

 

 

 

 

 

N.C.

 

 

 

4192SD

 

PARK. QUINCY, MA. 02269). PRINTED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.C.

 

 

 

 

SMOKE

 

 

NOTE:

 

 

 

 

9.6VDC - 13.8VDC,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INFORMATION DESCRIBING PROPER

 

 

 

 

 

750mA maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHEN POWERING UP

 

 

 

Note: Include current drawn

 

N.C.

 

 

 

N.O.

 

N.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION, OPERATION, TESTING,

THE PANEL, PLUG THE

 

 

by keypads and polling loop

 

 

 

 

 

 

 

 

 

N.O.

 

N.C.

 

 

 

4190

 

MAINTENANCE, EVACUATION PLANNING

SIREN

 

 

 

Burg.

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANSFORMER IN BEFORE

devices when making

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SN

 

AND REPAIR SERVICE IS TO BE

CONNECTING THE BATTERY.

 

 

auxiliary power calculations.

 

 

 

Usage

2k EOLR

2k EOLR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2k EOLR

 

 

 

 

 

 

 

PROVIDED WITH THIS EQUIPMENT.

 

ALARM SOUNDER OUTPUT 10VDC - 13.8VDC

 

 

 

 

N.O.

 

 

(note 1)

(note 1)

 

 

 

 

 

 

 

 

 

 

 

 

Notes For UL Household Fire Installations

 

 

 

 

 

 

Zone resistance (Excluding EOLR):

 

 

 

 

(note 1,4)

 

 

 

USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Use 12VDC, 14AH battery

2k EOLR

ZONE 1,8: 100 OHMS MAXIMUM

Polling loop rating: 64mA max. See

 

 

2. Maximum auxiliary current,

(note 1,2)

ALL OTHER ZONES: 300 OHMS MAXIMUM

Installation Instructions for maximum

COMPLIES WITH FCC RULES, PART 68

 

including polling loop 300mA

Zone response time:

number of devices supported and

FCC REGISTRATION NO. AC398U-68192-AL-E

 

 

 

3. Combined alarm and auxilary power output

 

ZONES 1-8: 350mSec-500mSec

maximum wire run length

RINGER EQUIVALENCE: 0.7B

 

and polling loop current must be limited to 750mA

 

 

for UL985 Household Fire Installations.

 

ZONE 9: Programmable for

CONNECTION OF THE FIRE ALARM SIGNAL

 

 

 

ALL CIRCUITS ARE

Fast: 10mSec-15mSec

TO A FIRE ALARM HEADQUARTERS OR A

THIS DEVICE COMPLIES WITH PART 15 OF

 

POWER LIMITED.

Normal: 350mSec-500mSec

CENTRAL STATION SHALL BE PERMITED

FCC RULES. OPERATION IS SUBJECT TO THE

 

 

(default response)

ONLY WITH THE APPROVAL OF THE LOCAL

FOLLOWING TWO CONDITIONS: (1) THIS DEVICE

 

 

AUTHORITY HAVING JURISDICTION. THE

MAY NOT CAUSE HARMFUL INTERFERENCE, AND

 

 

 

 

 

 

BURGLAR ALARM SIGNAL SHALL NOT BE

(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE

 

 

 

CONNECTED TO A POLICE EMERGENCY

RECEIVED, INCLUDING INTERFERENCE

 

 

 

NUMBER.

THAT MAY CAUSE UNDESIRED OPERATION.

 

 

ADEMCO VISTA-40

 

 

 

 

 

SUMMARY OF CONNECTIONS

 

VISTA-40-SOC-V1

VISTA-40 Summary of Connections Diagram

Page 35
Image 35
Honeywell 2-Partitioned Security System manual ADEMCO VISTA-40, Summary Of Connections