Partition-Specific Fields

(Duplicate this page for each partition in the installation.) To program these fields,

1.Press *91 to select a partition.

2.Enter a partition-specific field number (ex. *09).

3.Make the required entry.

4.Repeat steps 1-3 for the other partition in the system.

PARTITION #____ PROGRAM FIELDS

1st Page Fields

 

*09

ENTRY DELAY #1

[02]

 

00, 02-15 times 15 seconds.

 

 

Maximum 03 for UL Listed installations.

 

*10

EXIT DELAY #1

[04]

*88 BURG. ALARM COMM. DELAY

[0]

1=16 seconds; 0=no delay. Must be "0" for UL installations.

*90 SEC. SUBS. ACCT #

 

 

 

Enter 00-09; B-F (11-15)

[15 15 15 15]

 

 

 

 

2nd Page Fields

00, 03-15 times 15 seconds.

Maximum 04 for UL Listed installations.

*11

ENTRY DELAY #2

[06]

 

 

 

00, 02-15 times 15 seconds.

 

 

 

 

 

 

 

 

Maximum 03 for UL installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*12

EXIT DELAY #2

[08]

 

 

 

00, 03-15 times 15 seconds.

 

 

 

 

 

 

 

 

Maximum 04 for UL installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*13

ALARM SOUNDER DURATION

[04]

 

 

 

01-15 times 2 minutes.

 

 

 

 

 

 

 

 

Must be minimum 16 minutes for UL installations.

 

*16

CONFIRMATION OF ARMING DING

[0]

 

 

 

1=enable; 0=disable.

 

 

 

 

 

 

 

 

Must be "1" for UL installations.

 

 

 

 

 

 

 

*22

KEYPAD PANIC ENABLES [001]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1=enable; 0=disable

995 996

 

999

*23

MULTIPLE ALARMS

[1]

 

 

1=yes; 0=no. Must be 1 for UL installations.

1*43 PERM. KEYPAD BACKLIGHT

[0]

 

1=enable; 0=disable When disabled, display lights when

any key is pressed, and turns off after period of keypad

inactivity.

 

 

1*45

EXIT DELAY SOUNDING

[0]

 

 

 

1=enable; 0=disable. Produces quick beeping during exit

 

 

delay if enabled.

 

 

 

 

1*47

CHIME ON BELL 1

[0]

 

 

 

 

 

1=enable; 0=disable

 

 

 

 

1*52

SEND CANCEL IF ALARM + OFF

[0]

 

 

 

 

 

1=no restriction; 0=within Bell Timeout period only

 

 

 

 

 

 

 

 

1*76

ACCESS CONTROL RELAY FOR PART.[00]

 

Relay will be pulsed for 2 seconds whenever code + [0] is pressed. Enter 00-08; 00=none. Must be "00" for UL installs.

3rd Page Fields

2*18 ENABLE GOTO FOR THIS PARTITION

[0]

1=Allow log-on from other partitions; 0=disable

*29 QUICK ARM

[1]

1=yes; 0=no

2*20 ENABLE J7 TRIGGERS BY PARTITION

[1]

0=disable; 1=enable for

*32

PRIM. SUBS. ACCT #

 

 

 

 

 

 

 

 

Enter 00-09; B-F (11-15)

[15 15 15

15]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*38

PREVENT ZONE XX BYPASS

 

[00]

 

 

 

001-64; 000 if all zones can be bypassed

 

 

 

 

 

 

 

*39

ENABLE OPEN/CLOSE REPORT

 

 

[1]

 

 

 

 

 

 

 

FOR INSTALLER CODE

 

 

 

 

 

 

 

 

 

1=enable; 0=disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*84

SWINGER SUPPRESSION

 

[03]

 

 

01-15 alarms; Must be "00" (disabled) for UL installations.

*85 ENABLE DIALER REPORTS FOR PANICS & DURESS

1=enable; [0=disable]

995 996 999 Duress

*87 ENTRY WARNING

[1]

1=continuous; 0=3 beeps

SUMMARY OF PROGRAMMING COMMANDS

To enter program mode, enter installer code + [8] + [0] + [0]

To set standard defaults, press *97

To change to next page of program fields, press *94

To return to previous set of fields, press *99

To erase account and phone number field entries, press [*] + field number + [*]

To assign zone descriptors, press #93 + follow menu prompts

To add custom words, press #93 + follow menu prompts

To enter Installer's Message, press #93 + follow menu prompts

To exit program mode, enter *99 OR *98: *99 allows re- access to programming mode by installer code. *98 prevents re-access to programming mode by installer code.

– 9 –

Page 9
Image 9
Honeywell 2-Partitioned Security System, VISTA-40 Partition-Specific Fields, Partition # Program Fields, 1st Page Fields