Device Programming

This menu is used to program keypads, receivers, and relay modules, etc.

Device Address 00 is always set as an alpha keypad assigned to Partition 1 with no sounder suppression options, and these settings cannot be changed.

From Data Field Programming mode, press [#]93 to display "ZONE PROG?" Press 0 repeatedly to display "DEVICE PROG?"

PROMPTEXPLANATION

 

DEVICE PROG?

 

 

1=YES 0=NO

0

 

 

 

 

 

 

 

 

DEVICE ADDRESS

 

 

01-15, 00=QUIT

01

 

 

 

 

 

 

 

DEVICE TYPE

0

Press 1 to enter Device Programming.

The device address identifies the device to the control. Enter the 2-digit device address number to match the device’s physical address setting (01-15).

NOTE: If using the 4285/4286 Voice Module, it must be used at Device Address 04.

Select the type of addressable device as follows:

0

= device not used

3

= RF receiver (5881)

1

= alpha keypad (6139/6160)

4

= output relay module (4204)

2

= fixed keypad (6137/6150)

5

= voice (VIP) Module (4285/4286)

Press [] to accept entry.

Alpha Keypad

PROMPTEXPLANATION

01 CONSOLE PART.

1

01 SOUND OPTION

00

If you selected device type 1 (alpha keypad) or 2 (fixed keypad), this prompt appears. Enter the addressable device’s default partition number (1 to maximum number of partitions programmed for system in field 2*00). This is the primary partition for the device.

Press [] to accept entry.

Keypads can be individually programmed to suppress arm/disarm beeps, entry/exit beeps and chime mode beeps. This helps prevent unwanted sounds from disturbing users in other areas of the premises.

Enter a number 00-03for the keypad sounding suppression options desired for the keypad as follows: 00 = no suppression

01 = suppress arm/disarm & entry/exit beeps

02 = suppress chime mode beeps only

03 = suppress arm/disarm, entry/exit and chime mode beeps Press [] to accept entry.

RF Expander

PROMPTEXPLANATION

01 RF EXPANDER

 

HOUSE ID

00

If you selected device type 3 (RF receiver), this prompt appears. Enter the 2-digit House ID (00-31). This is required if you are using a wireless keypad (5827/5827BD).

Press [] to accept entry.

VIP Module

PROMPTEXPLANATION

01 MODULE PART.

1

If you selected device type 5 (VIP Module), this prompt appears. Enter the partition number 1-2in which the module is located.

Press [] to accept entry.

Press 00 + [] to exit Menu mode. Press 99 to exit Program mode.

– 21 –

Page 21
Image 21
Honeywell 2-Partitioned Security System, VISTA-40 manual Device Programming, Alpha Keypad, RF Expander, VIP Module