Entering Wireless Keys

PROMPT

10 INPUT S/N:

L

A XXX-XXXX

-

EXPLANATION

If you entered RF, BR, UR or SL for the Input Type, this screen displays. Otherwise the summary screen for the next zone displays.

Enter the 7-digit serial number, using one of the following methods:

a.Transmit two open and close (or close and open) sequences. For a button-type transmitter, press and release the button, wait approximately 4 seconds, then press and release the button a second time.

OR

b.Manually enter the 7-digit serial number printed on a label on the transmitter, using the alpha keypad. Then press the [] key, the cursor will move to the “L” position. You can edit the loop number, if necessary. When the loop number is acceptable, press [].

OR

c.Press key [C] to copy the last serial number enrolled (used when programming a transmitter with several input loops).

Remember, you can use the [A] key to move to the right or the [B] key to move to the left. You can also use the [#] key to back up without saving.

10 INPUT S/N:

L

A022-4064

1

Press [] to accept the serial number and advance to the “L” position (if method “a” or “c” was used), then enter the loop number.

If necessary, press the [#] key to back up without saving, and re-enter or edit the serial number before pressing [] to save

The system checks for a duplicate. If a duplicate serial/loop number combination is found, the keypad will emit a single long beep, and display the serial number along with a “?” for the loop number, allowing you to re-enter the correct loop number.

10 INPUT S/N:

L

A000-0000

1

XMIT TO CONFIRM

PRESS TO SKIP

To Delete an Existing Serial Number, enter 0 in the loop number field. The serial number will change to “0”s.

If 0 was entered in error, simply re-enter the loop number or press [#], and the serial number will return to the display.

The prompt to confirm appears. This prompt only appears if you answered “Yes” at the “SET TO CONFIRM?” prompt.

The system enters a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate the loop input or button that corresponds to this zone. At any time during this step, you may press the [] key on the keypad to save the serial and loop number combination without confirming.

Entd A022-4063 1 Rcvd A022-4064

If the serial number transmitted does not match the serial number entered, a display similar to the one at the left appears. If the loop number does not match, it also is displayed.

If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display for the next zone does not appear), press the [#] key twice and then enter or transmit the correct serial number.

Activate the button on the wireless key again after re-entering the serial number.

Zn

ZT

P

RC

In

L

11

00

1

10

00

1

If the serial number transmitted matches the serial number entered, the system beeps 3 times and advances to the summary display for the next zone's programming.

After all the zones have been programmed, enter 00 for the zone number to quit.

After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information (zone number, zone type, etc.) relevant to that device.

Entering Wireless Keys

If you pressed the D key previously to enter defaults for 5804 and/or 5804BD wireless keys, the following screens appear:

PROMPTEXPLANATION

FROM TEMPLATE

1–61

L01 02 03 04 ZT 23 22 21 23 1

Enter template number (1–6).

1–3 = 5804 templates; 4–6 = 5804BD templates. See the defaults provided for each template in the chart that follows these procedures.

Select from templates. Press [] to display template (template 1 shown selected). Note: If necessary, press [#] to back up and re-enter template number.

Press [#] if you want to return to zone attributes screen.

When you press [], the selected template is displayed.

Top line of display represents loop numbers; bottom line represents zone type.

Press [] to accept template.