Port Status and Configuration

Viewing Port Status and Configuring Port Parameters

Display real-time status information about all installed transceivers, including non-operational transceivers.

Figure 10-8 shows sample output from the show tech transceivers command.

ProCurve# show tech

transceivers

 

Transceiver

Technical

Information:

Part #

Port #

Type

Prod #

Serial #

9-------

+-----------

+

--------+

------------------CN605MP23K

+----------

1000SX

J4858B

10

1000LX

J4859C

H117E7X

2157-2345

Figure 10-8. Example of Show Tech Transceivers Command

Operating Notes:

The following information is displayed for each installed transceiver:

Port number on which transceiver is installed.

Type of transceiver.

Product number—Includes revision letter, such as A, B, or C. If no revision letter follows a product number, this means that no revision is available for the transceiver.

Part number—Allows you to determine the manufacturer for a spec­ ified transceiver and revision number.

For a non-ProCurve installed transceiver (see line 23 Figure 10-8), no transceiver type, product number, or part information is displayed. In the Serial Number field, non-operationalis displayed instead of a serial num­ ber.

The following error messages may be displayed for a non-operational transceiver:

Unsupported Transceiver. (SelfTest Err#060) Check: www.hp.com/rnd/device_help/2_inform for more info.

This switch only supports revision B and above transceivers. Check: www.hp.com/rnd/device_help/ 2_inform for more info.

Self test failure.

Transceiver type not supported in this port.

10-15