4.Slide the control panel right-arm mount to the right to remove it from the scanner chassis. Figure 1-62Remove the control panel and right-arm mount (3 of 3)

Reinstall the control panel and right-arm mount

1.Slide the control panel right-arm mount assembly into the mounting points on the scanner chassis.

2.Install three screws (callout 1) and attach the grounding wire (callout 2).

IMPORTANT: The grounding wire and the two FFCs must move freely. If the grounding wire is tangled with the FFCs, or is retracted too far into the control panel swivel, it might be too short to reach the mounting point on the chassis.

Figure 1-63Reinstall the control panel and right-arm mount (1 of 2)

1

2

ENWW

Removal and replacement procedures 49

Page 75
Image 75
HP 400 manual 63Reinstall the control panel and right-arm mount 1