Paw Carrier (Paw Active)

(HP Authorized Service Providers Only)

Required Equipment

Appropriate ESD station

Torx #6 screwdriver

Two small flat tip screwdrivers (or similar prying devices)

Probe

Removal Procedure

1.Follow the Logic Board PCA Removal Procedure.

2.Remove the Mylar Mouse Shield. Refer to the below illustration for location of components.

3.The Mouse Eject Arm and Eject Arm Spring may be removed at this point for convenience.

4.Gently bend the Pivot Bracket Tabs upward. Take caution not to break these tabs. If this occurs the Bottom Case must be replaced.

5.Remove the Pivot Bracket.

6.Lift the Paw Carrier from the plastic posts holding it in place.

Mylar Mouse

Shield

Pivot Bracket

Paw Carrier

Pivot Bracket

Tabs (Qty 2)

Mouse Eject

Arm

 

 

Eject Arm

Bottom Case

 

Spring

Figure 24 - Paw Carrier Removal

Replacement Procedure

1.To replace the Paw Carrier, reverse the steps in the Removal Procedure.

2.Follow the Logic Board PCA Replacement Procedure to replace the Logic Board and remaining components.