| test (low 640k). | |
|
| x = 64k bank no. with problem (i.e. | |
|
| 6204 = bank 4 is bad = address | |
|
| range 40000h to 4ffffh) | |
| 6300h | I/O channel check came active during | |
|
| write read test of protected mode ram | |
|
| 63xx = xx = 256k ram bank/block | |
|
| with problem | |
BIOS and Memory |
|
| |
6500h | shadow RAM BIOS failed | ||
|
|
| |
| 6510h | shadow RAM video BIOS failed | |
| 6520h | shadow RAM option ROM failed | |
| 65A0h | A000 shadow RAM test failed | |
| 65B0h | B000 shadow RAM test failed | |
| 65C0h | C000 shadow RAM test failed | |
| 65D0h | D000 shadow RAM test failed | |
| 65E0h | E000 shadow RAM test failed | |
| 65F0h | F000 shadow RAM test failed | |
8259 Interrupt |
|
| |
07000h | 7XYY where | ||
Functionality Errors |
| X | = 0 master's mask reg. failed |
|
| X | = 1 slave's mask reg. failed |
|
| YY = XOR of value read & written to | |
|
| the mask reg | |
| 07400h | IRQ 0 error | |
| 07500h | IRQ 8 error | |
| error code 7600 was previously used | ||
Hard Disk Errors |
|
| |
8310h | controller fail | ||
| 8311h | fixed disk fail | |
| 8312h | drive splitting failure | |
| error codes | ||
| used |
|
|
Flexible Disk Errors |
|
| |
9X0Z | X = drive number (0..3 correspond to | ||
|
| drives A:, B:, FDE#1, FDE#2) | |
|
| Z = determined by the following | |
|
| equates | |
| 9000H | FDC input error | |
| 9001H | FDC output error | |
| 9002H | FDC seek error | |
| 9003H | FDC recall error | |
| 9005H | FDC reset error | |
| 9006H | FDC wrong drive | |
| 9008H | FDC no interrupt | |
| 9009h | FDC track 0 error | |
| error codes 90XX and 98XX were previously used | ||
80x87 Numerical Co- |
|
| |
0a001h | there is no 80287 in the system | ||
Processor Errors |
|
|
|
| 0a002h | problem with the 80287's registers | |
| 0a003h | problem with the 80287's stack |
73