Chapter 1, Getting Started

Step 3: Configure the Software

5

Scroll to and select TX Measurement Path Loss. Enter the loss (through cables, couplers, and attenuators)

between your base station’s transmitter test port and the RF IN/OUT port of the PCS Interface.

Configuration Information Menu

Return to Main Menu

Base Station Channel . . . . . . . . . 220

Base Station PN Offset . . . . . . . . 16

Base Station Reference Freq. . . 19.6608 MHz

Base Station Reference To . . . . SYNTH REF IN

Base Station Power Out . . . . . . . 1.00000 Watt(s)

TX Measurement Path Loss . . . . 0.5 dB

RX Measurement Path Loss . . . . 4.0 dB

Connection Drawing Menu

PCS Band = North American Band

Beep = Off

Save Info To Memory

Load Info From Memory

Enter the value into the highlighted field. The Software will compen- sate for cable loss, improving measurement accuracy.

6

Scroll to and select RX Measurement Path Loss. Enter the loss of the RF cable (include loss through split-

ters, and so forth) between your base station’s receiver test port and the RF IN/OUT port of the PCS Interface.

Configuration Information Menu

Return to Main Menu

Base Station Channel . . . . . . . . . 220

Base Station PN Offset . . . . . . . . 16

Base Station Reference Freq. . . 19.6608 MHz

Base Station Reference To . . . . SYNTH REF IN

Base Station Power Out . . . . . . . 1.00000 Watt(s)

TX Measurement Path Loss . . . . 0.5 dB

RX Measurement Path Loss . . . . 4.0 dB

Connection Drawing Menu

PCS Band = North American Band

Beep = Off

Save Info To Memory

Load Info From Memory

Enter the value into the highlighted field. The Software will compen- sate for cable loss, improving measurement accuracy.

7 Scroll to and select PCS Band.

Configuration Information Menu

Return to Main Menu

Base Station Channel . . . . . . . . . 220

Base Station PN Offset . . . . . . . . 16

Base Station Reference Freq. . . 19.6608 MHz Base Station Reference To . . . . SYNTH REF IN Base Station Power Out . . . . . . . 1.00000 Watt(s) TX Measurement Path Loss . . . . 0.5 dB

RX Measurement Path Loss . . . . 4.0 dB Connection Drawing Menu

PCS Band = North American Band Beep = Off

Save Info To Memory Load Info From Memory

8

Scroll to and select your band of interest.

 

See "Selecting a PCS Band" on page 51.

PCS Band Selection Menu

North American Band

Korean Band Proposal 0

Korean Band Proposal 1

19

Page 19
Image 19
HP 83236B S Interface manual Scroll to and select your band of interest