Installing

Connect the cables

Connect Fibre Channel devices to the switch

Connect power to the switch

Connect Fibre Channel devices to the switch

Connect cables to the SFP transceivers and their corresponding devices, and then apply power to the devices. LC-type duplex fiber optic cable connectors are designed for use with the SFP transceivers. Duplex cable connectors are keyed to ensure proper orientation.

GL_Ports self configure as FL_Ports when connected to loop of public devices or F_Ports when connected to a single device. G_Ports self configure as F_Ports when connected to single public devices.

Connect power to the switch

WARNING: This product is supplied with a 3-wire power cable and plug. Use this power cable in conjunction with a properly grounded outlet to avoid electrical shock. An electrical outlet that is incorrectly wired could place hazardous voltage on metal parts of the switch chassis.

A different power cable than the one supplied may be required in some countries.

For 125 Volt electrical service, the cable must be rated at 10 Amps and be approved by UL and CSA.

For 250 Volt electrical service, the cable must be rated at 10 Amps, meet the requirements of H05VV-F, and be approved by VDE, SEMKO, and DEMKO.

1.Connect the power cord to the AC power port on the switch chassis and to a grounded AC outlet or uninterruptible power supply.

2.Verify that the chassis LEDs illuminate, followed by all port Logged-in LEDs.

3.After a few moments, verify that the chassis System Fault LED is extinguished while the Input Power LED and Heartbeat LED remain illuminated.

4.Wait approximately one minute for the POST to complete, and the following LED pattern to begin:

The Input Power LED remains illuminated indicating that the switch logic circuitry is receiving DC voltage. If not, contact your authorized maintenance provider.

The Heartbeat LED indicates the results of the POST. The POST tests the condition of firmware, memories, data-paths, and switch logic circuitry. If the Heartbeat LED blinks steadily about once per second, the POST was successful, and you can continue with the installation process. Any other blink pattern indicates that an error has occurred. See Heartbeat LED blink patterns” on page 42 for more information about error blink patterns.

HP StorageWorks 2/8q Fibre Channel Switch Installation Guide