Model 5328A

General Information

Table 7-3. 5328A Counter Specifications (Continued)

CHANNEL C

TIME BASE

Input Characteristics

Outputs: 1 MHz and 10 MHz available at rear

Range: 30 MHz to 500 MHz direct count

panel BNC in standby and operate modes

Sensitivity: 15 mV rms, 30 MHz—500 MHz

Output level: 1 volts rms into 50f)

Trigger level: 0 volts

External Input: Operates from 1, 2.5, 5, and 10

Impedance: 50fl nominal

MHz inputs at 1V rms.

Maximum Input: 5 volts rms

Input impedance 1 K~l<30 pF

Input protection: Input BNC fused; accessible

Counter automatically switches to

from front panel. protected to 200 volts peak.

external mode when external input is

overload Indicator: flashing indicator warns

present.

of potential overload conditions.

Oscillator Aging Rate: <5x1010/day after

Resolution: 1 MHz to 0.1 Hz in decade steps

24-hour warmup. Oscillator oven is

Accuracy: ±1 count ± time base error

energized when power cable is connected

Display: Hz, kHz, MHz

to line voltage.

 

 

1-4

Page 19
Image 19
HP E42 manual A Counter Specifications, Channel C Time Base, Trigger level 0 volts, Maximum Input 5 volts rms