Troubleshooting

Diagnostic Flowcharts

Flowchart 1 Procedures

Check dmesg/syslog output and look for error messages pertaining to gelan/igelan. Also, check nettl log messages. If errors, check card installation and reset and/or reseat card.

Verify LEDs. If 1000Base-SX link LED = OFF or for gelan, 1000Base-T all speed LEDs = ON, check card installation and reset and/or reseat card. If LEDs are then displayed correctly, continue to Link Level Test.

If 1000Base-T all speed LEDs = OFF or for gelan, 1000Base-SX Link LED = Flashing, check for incorrect or faulty network cable or connector. Ensure that switch is capable of 1000 Mbps operation. Ensure that the switch (or immediate link partner) and card are set to same autonegotiation settings. Then go to Configuration Tests. Otherwise, if 1000Base-SX link LED or one of 1000Base-T speed LEDs is on, continue to Link Level Test.

NOTE

Refer to Table C-1, “LED Description and Status for 1000Base-SX”and Table C-2, “LED

 

Description and Status for 1000Base-T”for LED status.

 

On a 1000Base-SX card, if both Link and Activity LEDs are on and there is no network

 

connectivity, it could mean that the I/O cage is not seated well. Remove and reseat the

 

entire PCI I/O cage and reboot.

Chapter 4

31

Page 33
Image 33
HP HSC/I 1000Base-SX, I 1000Base-T manual Flowchart 1 Procedures