Upgrades and Global Instant Capacity

Be careful before upgrading or changing hardware or operating systems for any member of a GiCAP group. If a member of a GiCAP group changes hardware in such a way that the hardware is no longer compatible with the group, then the group is considered to be out of compliance and group functions are restricted.

Also, the number of available sharing rights is adjusted whenever an Instant Capacity codeword is applied to a GiCAP member system that modifies the number of cores without usage rights on that member. (RTU and AddOn codewords for cores cause such adjustments.)

If more sharing rights are in use than were purchased for the Group Manager, all groups managed by that Group Manager are out of compliance and all group functions are restricted until the problem is resolved. The problem can be resolved by purchasing and applying additional sharing rights to the Group Manager, purchasing and applying core usage rights to one or more group members, or removing one or more group members from their group.

When such an incompatibility is detected, the GiCAP Group Manager sends email to the local root account and to the registered contact email address for each member of the group.

Adding New Partitions

When reconfiguring a member system by adding or deleting an nPartition, use the icapmanage -ucommand to add or remove host names to or from the member. For example, enter this command to add a new nPartition with hostname hostC to member memberA:

icapmanage -u -m memberA -h hostC

To remove a host name, prefix the host name with “!”, as in !hostC. You can also add or remove a list of hosts; separate the additions from the removals with a “!”, as in hostA,hostB!hostC,hostD to add hostA and hostB while removing hostC and hostD.

If the Group Manager runs on a partitionable system, changing the configuration of the partitions may render the Group Manager inoperative. This is because the Group Manager database is tied to the serial number of the complex, the nPartition ID number, and a virtual partition ID number. Although adding or modifying partitions does not change these IDs, they are changed if a partition is deleted and then re-created on the Group Manager.

Upgrades and Global Instant Capacity 121

Page 121
Image 121
HP Instant Capacity (iCAP) manual Upgrades and Global Instant Capacity, Adding New Partitions