Applying a Right To Use (RTU) Codeword

Unless you have a balance of Instant Access Capacity (IAC) or temporary capacity (or usage rights available from a GiCAP group), you must purchase additional usage rights before activation of an inactive core. To purchase additional usage rights:

1.Contact your HP sales representative to purchase the appropriate Instant Capacity RTU products.

2.Acquire an RTU codeword from the Utility Pricing Solutions web portal at http:// www.hp.com/go/icap/portal.

3.Apply the RTU codeword using the icapmodify -Ccommand. Note that the -Coption is in uppercase.

Example Example 4-2shows how to apply a core RTU codeword using the icapmodify -Ccommand.

Example 4-2 Applying an RTU Codeword (HP-UX)

>/usr/sbin/icapmodify -C mDwvj0M.fbHhKC9.byrgc8k.Pc7PjMt-1cp63H9.29xrDLU.g2CJhQM.RzuYyd6

The following valid codeword has been applied to the complex:

Right to Use Codeword 1 Core(s)

Use icapstatus(1M) to see the results of the application of this codeword.

NOTE: Application of Right to Use codewords does not result in the activation of components. Use icapstatus(1M) to see the results of the application of this codeword.

For cores: Use icapmodify(1M) to activate the cores.

For cell boards and memory: Use parmodify(1M) to activate cells by setting the use_on_next_boot flag to ‘y’ or use parmgr(1M).

Application of the codeword increments the count of Additional cores that can be activated with current usage rights (limited by the Number of inactive cores) in the output of the icapstatus command.

IMPORTANT: RTU codewords are based on both the serial number of a system and a unique sequencing value for that server. These codewords must be applied in the sequence in which they are obtained for a particular server. They can be applied to any partition on the server.

Figure 4-1 (page 56) illustrates the process of ordering Instant Capacity components and ordering and applying usage rights.

Applying a Right To Use (RTU) Codeword 55

Page 55
Image 55
HP Instant Capacity (iCAP) manual Applying a Right To Use RTU Codeword, Example 4-2 Applying an RTU Codeword HP-UX