Error conditions

Depending on your system configuration, you may be able to view error messages as follows:

In Remote Web Console (Status tab)

In Command View Advanced Edition (“Alerts” panel).

In Command View (Event History or Event Notification panels).

Error Condition

Recommended Action

 

 

The logical devices are not

Verify that the READY indicator lights on the disk array are ON.

recognized by the host.

Verify that fiber cables are correctly installed and firmly connected.

 

 

Verify that the target IDs are properly configured. The LUNs for each

 

TID must start at 0 and continue sequentially without skipping any

 

numbers.

 

Verify that the TIDs/WWNs on each bus are unique. Do not install two

 

devices with the same ID on the same bus.

 

Recheck the buses for new devices.

 

Verify that LUSE devices are not intermixed with normal LUNs on the

 

same port.

 

Verify that the maximum number of LUSE devices per port has not

 

been exceeded.

 

Verify that the disk array host mode is set correctly.

 

 

The host does not reboot

If you power off the host without executing the shutdown process, wait

properly after hard shutdown.

three minutes to allow the disk array’s internal timeout process to

 

purge queued commands. If the host restarts while the disk array is

 

processing queued commands, the host may not reboot successfully.

 

 