SmartCardUidOid—string value. The OID associated with the entered SmartCardUidType. Not all Types require an OID. An entry is required is SmartCardUidType=8. Default is blank.

SmartCardAutoDisconnect—integer value, 0 or 1. If set to 1, automatically disconnect the session when the smart card is removed. Note that Active Directory policy settings may affect the actual behavior of this property. Active Directory options include leave as is, password lock, and log off. Active Directory does not include a disconnect option, so you must use SmartCardAutoDisconnect for that functionality. Default is 1.

User Interface Customization Settings

UiMode—integer value, 0, 1 or 2. Select the type of user interface to display.

0 (default)—HP SAM Server, User name, and Domain fields visible in the user interface.

1—show the UPN mode, where the Domain field is not shown. The user must use the format username@domain.

2—show smart card mode, where both the User Name and Domain fields are hidden, and a message displays asking that the user insert the smart card. The Connect button is disabled when no smart card is inserted. For the Blade Workstation Client Embedded OS and Linux Client, this value (2) is treated as a 1.

Banner—string value, Allows a specified file to load as the banner image on the access device main dialog. The image must be in Windows Bitmap (BMP) format. A fully qualified path is required. The banner area is 385 x 60 pixels and 24-bit color. If you provide a file of different resolution, it is resized to fit in the banner area.

TitlebarText—string value. Allows overriding the default text in the titlebar with a specified string. By default, language-appropriate text displays.

ShowVersion—integer value, 0 or 1. If set to 1, displays the HP SAM client version text on the main window. Default is 1.

EnableOptionsButton—integer value, 0 or 1. If set to 1, the Options button on the main application dialog is visible. If set to 0, the button is not displayed. Default is 1.

EnablePassword—integer value, 0 or 1. When set to 1, shows the Password box on the access device user interface. When set to 0, the password box is not available. Default is 1.

UILanguage—language identifier. Supported identifiers include:

EN = English

FR = French

DE = German

JA = Japanese

KO = Korean

ZH-CN = Simplified Chinese

If the identifier is not supported or the property is not present in the file, the application default is US English. A language support DLL must be present to support the language. Not valid for the Blade Workstation Client series or Linux Client.