CE | Utility | Program |
| Diskette |
|
|
|
|
| |||
Note: | You can | download | the CE Utility Program Diskette | |||||||||
| from | the | IBM | website. |
|
|
|
|
| |||
Setting | the | LCD | Panel | ID |
|
|
|
|
| |||
There is an EEPROM in | the inverter which stores its sup- | |||||||||||
ported | LCD | type | ID | code. | If | you replace | a | LCD | with one of | |||
a different | brand | or use | a new inverter, | the | ID | information | ||||||
in | the | inverter | EEPROM | should | be | updated. |
|
|
|
Follow the steps below to set the LCD Panel ID:
1. Boot from the Utility Program Diskette.
2. SelectLCD Panel ID | Utility | from | PC | DOS | 7.0 |
|
|
|
| ||||
Startup | Menu. |
|
|
|
|
|
|
|
|
|
| ||
3. Follow the instructions on | the | screen to | read | the | |||||||||
current | or | to | set | a | new | LCD | Panel | ID | code. |
| |||
Note: | When | you | set | a | new | LCD | Panel | ID |
| and the | |||
| new LCD is not yet enabled (to function), | ||||||||||||
| connect an external CRT to see the program | ||||||||||||
| execution | process. |
|
|
|
|
|
|
| ||||
Attention: Make sure the new ID code you choose | |||||||||||||
corresponds | to | the | LCD | brand | and type. If you write a | ||||||||
wrong | ID into | the | inverter, just | reboot | and | ||||||||
the | program | and input | the | correct | ID | code. |
|
4.Restart the computer — the new LCD should work normally.
Note: If | the LCD | cannot display | after | changing | the | ID | ||
code, make | sure | you | write | the | correct | ID | code or | |
try | reconnecting | the | LCD FPC | cable | connectors. |
|
Setting the Thermal Sensor
The system is equipped with sensors to protect against system overheating. By setting the system and processor thermal thresholds, the system can turn on the cooling Fan ASM or shut down automatically when the temperature reaches the defined threshold parameters.
System | experiencing frequent | auto | sensor | shutdown | may | |||
need | to | reset the | thermal | sensor | threshold and | execute | ||
the Fan ASM test to ensure | the | normal operation | of the | |||||
cooling | Fan | ASM (refer | to “Fan ASM | Checkout” | on |
| ||
page | 29). |
|
|
|
|
|
|
|
Follow the steps below to set the thermal threshold:
1. Boot | from the Utility | Program | Diskette. |
2. SelectThermal Sensor Utility | from PC | DOS 7.0 | |
Startup | menu, then pressF4 . |
|
|