Symptom/Error |
| FRU/Action | in | Sequence |
|
|
|
| |||
|
|
|
|
|
|
|
| ||||
Battery | 1. | Remove | Battery | ASM | and | let | |||||
does | not | go higher |
| it | cool | for | 2 | hours. |
| ||
than | 90%. |
| 2. | Refresh battery (continue | |||||||
|
|
| |||||||||
|
|
|
| using battery in BIOS Setup | |||||||
|
|
|
| mode until power off, then | |||||||
|
|
|
| charge |
| battery). |
|
| |||
|
|
| 3. | Battery |
|
|
|
| |||
|
|
| 4. | DC/DC | & | Charger | board | ||||
|
|
| 5. | System board |
|
|
|
| |||
|
|
|
|
|
|
|
| ||||
System | configuration | 1. | Load | Setup | Defaults | and | |||||
does | not | match the |
| reboot |
| the | system. |
|
| ||
installed | devices. | 2. Reseat the Combobay ASM. | |||||||||
|
|
| |||||||||
|
|
|
|
|
| ||||||
System | hangs | 1. | Reseat | Hard Disk/Combobay | |||||||
intermittently. |
| ASM. |
|
|
|
|
|
| |||
|
|
| 2. | Fan ASM |
|
|
|
|
|
| |
|
|
| 3. | System board |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
Peripheral-Device-Related Symptom
Symptom/Error |
| FRU/Action | in Sequence | ||
|
|
|
| ||
External | display | doesSystem | board | ||
not | work | correctly. |
|
|
|
|
| ||||
USB does not work | System board | ||||
correctly. |
|
|
| ||
|
|
|
| ||
problems. | Ÿ | Run printer | |||
|
|
| Ÿ | Printer driver | |
|
|
| Ÿ | Printer cable | |
|
|
| Ÿ | System board | |
|
|
| |||
Serial or parallel | portŸ | Device driver | |||
device | problems. | Ÿ | Device cable | ||
|
|
| |||
|
|
| Ÿ | Device | |
|
|
| Ÿ | System board | |
|
|
|
|
|
|
Note: If you | cannot | find a | symptom | or an error in this list |
and the | problem | remains, | see | “Undetermined |
Problems” on page 47. |
|
|
Intermittent Problems
Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a hardware defect, such as cosmic radiation, electronic discharge, or software errors. FRU replacement should be considered
only when a recurring problem exists.
When analyzing an intermittent problem, do the following:
1.Run the advanced diagnostic test for the system board in loop mode at least 10 times.
2.If no error is detected, do not replace any FRUs.