Diagnostic Error Code

FRU/Action

 

 

 

000-197-XXX

1.

Make sure the component that is called

BIOS test warning

 

out is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

000-198-XXX

1.

If a component is called out, make sure

BIOS test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problems

 

 

section

 

 

 

000-199-XXX

1.

Go to the Undetermined problems

BIOS test failed, cause unknown

 

section

 

 

 

2.

Flash the system and re-test

 

3.

Replace component under function test

 

 

 

000-250-XXX

1.

Flash the system

BIOS APM failure

2.

System board

 

 

 

 

000-270-XXX

1.

Flash the system

BIOS ACPI failure

2.

System board

 

 

 

 

001-000-XXX

1.

No action

System Test Passed

 

 

 

 

 

001-00X-XXX

1.

System board

System Error

 

 

 

 

 

001-01X-XXX

1.

System board

System Error

 

 

 

 

 

001-024-XXX

1.

System board

System Addressing test failure

 

 

 

 

 

001-025-XXX

1.

Flash the system

System Checksum Value error

2.

System board

 

 

 

 

001-026-XXX

1.

Flash the system

System FLASH data error

2.

System board

 

 

 

 

001-027-XXX

1.

Run Setup

System Configuration/Setup error

2.

Flash the system

 

 

3.

System board

 

 

 

001-032-XXX

1.

System board

System Device Controller failure

 

 

 

 

 

001-034-XXX

1.

Reboot the system

System Device Buffer Allocation failure

2.

Flash the system

 

 

3.

Run memory test

 

4.

System board

 

 

 

001-035-XXX

1.

System board

System Device Reset condition detected

 

 

 

 

 

001-036-XXX

1.

System board

System Register error

 

 

 

 

 

38Hardware Maintenance Manual

Page 46
Image 46
IBM 6643, 2179 manual Hardware Maintenance Manual