Diagnostic Error Code

FRU/Action

 

 

 

030-00X-XXX

1.

SCSI signal cable

030-01X-XXX

2.

Check power supply

SCSI interface failure

3.

SCSI device

 

 

4.

SCSI adapter card, if installed

 

5.

System board

 

 

 

030-027-XXX

1.

SCSI signal cable

SCSI interface Configuration/Setup error

2.

Flash the system

 

 

3.

SCSI device

 

4.

SCSI adapter card, if installed

 

5.

System board

 

 

 

030-03X-XXX

1.

SCSI signal cable

030-04X-XXX

2.

Check power supply

SCSI interface error

3.

SCSI device

 

 

4.

SCSI adapter card, if installed

 

5.

installed System board

 

 

 

030-195-XXX

1.

Information

SCSI interface Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

030-196-XXX

1.

Press F3 to review the log file

SCSI interface test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

030-197-XXX

1.

Make sure the component that is called

SCSI interface test warning

 

out is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

030-198-XXX

1.

If a component is called out, make sure

SCSI interface test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problems

 

 

section

 

 

 

030-199-XXX

1.

Go to the Undetermined problems

SCSI interface test failed, cause unknown

 

section

 

 

 

2.

Flash the system and re-test

 

3.

Replace component under function test

 

 

 

035-000-XXX

1.

No action

RAID interface Test Passed

 

 

 

 

 

035-0XX-XXX

1.

RAID signal cable

RAID interface Failure

2.

RAID device

 

 

3.

RAID adapter card, if installed

 

4.

System board

 

 

 

035-195-XXX

1.

Information

RAID interface Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

48Hardware Maintenance Manual

Page 56
Image 56