Diagnostic Error Code

FRU/Action

 

 

 

011-000-XXX

1.

No action

Serial port Interface Test Passed

 

 

 

 

 

011-001-XXX

1.

Remove external serial device, if

Serial port Presence

 

present

 

 

 

2. Run setup, enable port

 

3.

System board

 

 

 

011-002-XXX

1.

System board

011-003-XXX

 

 

Serial port Timeout/Parity error

 

 

 

 

 

011-013-XXX

1.

System board

011-014-XXX

 

 

Serial port Control Signal/Loopback test

 

 

failure

 

 

 

 

 

011-015-XXX

1.

Wrap plug

Serial port External Loopback failure

2.

System board

 

 

 

 

011-027-XXX

1.

Run Setup, enable port

Serial port Configuration/Setup error

2.

Flash the system

 

 

3.

System board

 

 

 

011-03X-XXX

1.

System board

011-04X-XXX

 

 

Serial port failure

 

 

 

 

 

011-195-XXX

1.

Information

Serial port Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

011-196-XXX

1.

Press F3 to review the log file

Serial port test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

011-197-XXX

1.

Make sure the component that is called

Serial port test warning

 

out is connected and/or enabled

 

 

 

2. Re-run test

 

3. Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

011-198-XXX

1.

If a component is called out, make sure

Serial port test aborted

 

it is connected and/or enabled

 

 

 

2. Flash the system and re-test

 

3. Go to the Undetermined problems

 

 

section

 

 

 

011-199-XXX

1.

Go to the Undetermined problems

Serial port test failed, cause unknown

 

section

 

 

 

2. Flash the system and re-test

 

3. Replace component under function test

 

 

 

011-2XX-XXX

1.

External serial device

Serial port signal failure

2.

System board

 

 

 

 

014-000-XXX

1.

No action

Parallel port Interface Test Passed

 

 

 

 

 

Chapter 5. Symptom-to-FRU Index 43

Page 51
Image 51
IBM 2179, 6643 manual Symptom-to-FRU Index