IBM 2179, 6643 manual Diagnostic Error Code

Models: 2179 6643

1 128
Download 128 pages 12 Kb
Page 61
Image 61

Diagnostic Error Code

FRU/Action

 

 

 

175-199-XXX

1.

Go to the Undetermined problems

Thermal Sensor(s) test failed, cause

 

section

unknown

 

2.

Flash the system and re-test

 

 

3.

Replace component under function test

 

 

 

175-250-XXX

1.

Check fans

175-251-XXX

2.

Check Power supply

Thermal Sensor(s) limit error

3.

Microprocessor

 

 

4.

System board

 

 

 

185-000-XXX

1.

No action

Asset Security Test Passed

 

 

 

 

 

185-XXX-XXX

1.

Flash system

Asset Security failure

2.

System board

 

 

 

 

185-278-XXX

1.

Assure Asset Security Enabled

Asset Security Chassis Intrusion

2.

C2 Cover Switch

 

 

3.

System board

 

 

 

201-000-XXX

1.

No action

System Memory Test Passed

 

 

 

 

 

201-XXX-XXX

1.

Replace the memory module called out

System Memory error

 

by the test

 

 

 

2.

System board

 

 

 

202-000-XXX

1.

No action

System Cache Test Passed

 

 

 

 

 

202-XXX-XXX

1.

Cache, if removable

System Cache error

2.

System board

 

 

3.

Microprocessor

 

 

 

206-000-XXX

1.

No action

Diskette Drive Test Passed

 

 

 

 

 

206-XXX-XXX

1.

Diskette Drive Cable

Diskette Drive error

2.

Check power supply voltages

 

 

3.

Diskette drive

 

4.

System board

 

 

 

215-000-XXX

1.

No action

CD-ROM Drive Test Passed

 

 

 

 

 

215-XXX-XXX

1.

CD-ROM Drive Cable

CD-ROM Drive error

2.

Check power supply voltages

 

 

3.

CD-ROM drive

 

4.

System board

 

 

 

217-000-XXX

1.

No action

Hard Disk Drive Test Passed

 

 

 

 

 

217-25X-XXX

1.

Hard Disk Drive Cable

217-26X-XXX

2.

Check power supply voltages

Hard Disk Drive (IDE) error

3.

Hard Disk drive (IDE)

 

 

4.

System board

 

 

 

Chapter 5. Symptom-to-FRU Index 53

Page 61
Image 61
IBM 2179, 6643 manual Diagnostic Error Code