Diagnostic Error Code

FRU/Action

 

 

 

001-038-XXX

1.

Adapter card

System Extension failure

2.

System board

 

 

 

 

001-039-XXX

1.

Flash the system

System DMI data structure error

2.

System board

 

 

 

 

001-040-XXX

1.

Power-off/on system and re-test

System IRQ failure

2.

System board

 

 

 

 

001-041-XXX

1.

Power-off/on system and re-test

System DMA failure

2.

System board

 

 

 

 

001-195-XXX

1.

Information

System Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

001-196-XXX

1.

Press F3 to review the log file

System test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 

001-197-XXX

1.

Make sure the component that is called

System test warning

 

out is connected and/or enabled

 

 

 

2. Re-run test

 

3. Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

001-198-XXX

1.

If a component is called out, make sure

System test aborted

 

it is connected and/or enabled

 

 

 

2. Flash the system and re-test

 

3. Go to the Undetermined problems

 

 

section

 

 

 

001-199-XXX

1.

Go to the Undetermined problems

System test failed, cause unknown

 

section

 

 

 

2. Flash the system and re-test

 

3. Replace component under function test

 

 

 

001-250-XXX

1.

System board

System ECC error

 

 

 

 

 

001-254-XXX

1.

System board

001-255-XXX

 

 

001-256-XXX

 

 

001-257-XXX

 

 

System DMA error

 

 

 

 

 

001-260-XXX

1.

System board

001-264-XXX

 

 

System IRQ error

 

 

 

 

 

001-268-XXX

1.

Device on IRQ1

System IRQ1 failure

2.

System board

 

 

 

 

001-269-XXX

1.

Device on IRQ2

System IRQ2 failure

2.

System board

 

 

 

 

001-270-XXX

1.

Device on IRQ3

System IRQ3 failure

2.

System board

 

 

 

 

Chapter 5. Symptom-to-FRU Index 39

Page 47
Image 47
IBM 2179, 6643 manual Symptom-to-FRU Index