Table 31 (Page 2 of | 2). Dual Fiber Repeater Module LED Descriptions | |||
|
|
|
|
|
LED Name |
| Color | State | Description |
|
|
|
|
|
RI/RO |
| Green | On | Trunk enabled and operating |
|
|
|
|
|
|
|
| Off | Trunk disabled. |
|
|
|
|
|
|
|
| Blinking | Trunk enabled but not |
|
|
|
| operating normally |
|
|
|
|
|
JA1 and JA2 |
| Green | On | JADC card installed and |
|
|
|
| operating normally |
|
|
|
|
|
|
|
| Off | JADC card not installed |
|
|
|
|
|
|
|
| Blinking | JADC card failed diagnostics |
|
|
|
|
|
Port Status |
| Green | On | Port enabled and operating |
|
|
|
| normally on the ring |
|
|
|
|
|
|
|
| Off | Port disabled |
|
|
|
|
|
|
|
| 1 blink | Port enabled, no phantom |
|
|
|
|
|
Figure 114 shows the side view of the dual fiber repeater module. As can be seen, in addition to the 11 isolated segments and the mounting for one T-MAC, there is an 8-position DIP switch located on the module. These DIP switches are used in the absence of an installed management module in the 8260. However, if a management module is installed in your 8260, the setting of these DIP switches will be ignored unless ″DIP_CONFIGURATION″ is enabled for DMM. For more information, please refer to 4.2.4.4, ª Configuring DMM Deviceº on
page 50.
Figure 114. Dual Fiber Repeater Module Side View
The DIP switch settings on this module are identical to those of the