8260> show power slot all
Power Management Information
----------------------------
Slot Power Information:
Slot Class Admin Status Operating Status
---- ----- ------------ ----------------
1 10 ENABLE ENABLED
2 3 ENABLE ENABLED
3 3 ENABLE ENABLED
5 3 ENABLE ENABLED
6 9 ENABLE ENABLED
7 3 ENABLE ENABLED
8 N/A ENABLE ENABLED
9 N/A ENABLE ENABLED
10 N/A ENABLE ENABLED
11 N/A ENABLE ENABLED
12 N/A ENABLE ENABLED
13 N/A ENABLE ENABLED
14 N/A ENABLE ENABLED
15 N/A ENABLE ENABLED
16 N/A ENABLE ENABLED
8260>
 
Figure 45. Output from Show Power Class Comman d
Note that in this example, slots 8 thru 16 contain 8250 modules.
Power class is also used by the Controller module to power down media
modules in the case of overheating conditions that may be caused by fan
failures. This is discussed in Chapter 6, “8260 Intelligent Cooling Subsystem” on
page 91.
5.3 Configuring 8260 Power Supplies
The 8260 power management subsystem allows you to install up to a maximum
of four power supplies in an individual 8260. The power supplies are hot
pluggable and may be installed or removed while the hub is operating.
You can use the following management command to determine the number and
status of power supplies installed in your hub:

SHOW HUB

An example of the output from this command is shown in Figure 46 on page 77.
76 8260 Multiprotocol Intelligent Switching Hub