Table 21 4/32B SAN Switch power supply/fan assembly unit status LED

Manual background CAUTION:

Disassembling any part of the fan assembly voids the part warranty and regulatory certifications. There are no user-serviceable ports inside the Power Supply/Fan Assembly Unit.

Because the cooling system relies on pressurized air, do not leave any of the fan assembly slots empty longer than two minutes while the switch is operating. If a fan assembly fails, leave it installed in the switch until it can be replaced.

Maintain the two Power Supply/Fan assemblies in operating condition to provide redundancy.

Table 21 lists power supply/fan assembly unit status LED descriptions, and required actions.

Table 21 4/32B SAN Switch power supply/fan assembly unit status LED

LED name

LED color and

Description

Action required

 

behavior

 

 

 

 

 

 

Power Supply

No light

Power supply is not receiving

Verify that the power supply is on

Status

 

power or power is off.

and seated and the power cord is

 

 

 

connected to a functioning power

 

 

 

source.

 

Steady green

Power supply is operating

No action required.

 

 

normally.

 

 

 

 

 

System Status

No light

System is off, boot is not complete,

Verify that the system is on and

 

 

or boot failed.

booting is complete.

 

Steady green

System is on and power supplies

No action required.

 

 

are functioning properly.

 

 

Steady Amber

Boot failed and system is faulty.

Perform the following steps:

 

(for more than 5

 

1.

 

seconds)

 

Connect a serial cable to the

 

 

 

system.

 

 

 

2.

 

 

 

Reboot the system.

 

 

 

3.

 

 

 

Check the failure indicated on

 

 

 

the system console.

 

 

 

4.

 

 

 

Contact HP Technical Support.

 

Flashing amber

Attention is required. A number

Check the management interface

 

or green

of variables can cause this status

and the error log for details on the

 

 

including a single power supply

cause of the status. Contact HP

 

 

 

 