IBM AA-RWF3A-TE manual How to determine to replace the Power Supply/Fan Assembly Unit

Models: AA-RWF3A-TE

1 159
Download 159 pages 29.86 Kb
Page 108
Image 108

LED name

LED color and

Description

Action required

 

behavior

 

 

 

 

 

 

 

 

failure, a fan failure, or one or

Technical Support.

 

 

more environmental ranges has

 

 

 

exceeded.

 

 

 

 

 

How to determine to replace the Power Supply/Fan Assembly Unit

Verifying if the Power Supply requires replacing:

Check the Power Supply status LED next to the I/O switch. If the Power Supply status LED is not on, verify that the Power Supply is on and seated and the power cord is connected to a functioning power source. If the light does not turn green, the Power Supply needs to be replaced.

In Advanced Web Tools, click the Power Status icon.

Type psShow at the command prompt to display Power Supply status as follows: switch:admin> psshow

Power Supply #1 is OK Power Supply #2 is OK

Verifying if the Fan Assembly requires replacing:

Check the System Status LED. If the System Status LED is flashing amber and green, it could mean the fan has failed. Check the management interface and the error log for details on the cause of status.

In Advanced Web Tools, check the Fan Status icon background color. It will be either yellow or red if the fan has failed. When the fan is functioning correctly, the background color is green.

Type fanShow at the command prompt to display fan status as follows: switch:admin> fanshow

Fan 1 is OK, speed is 7105 RPM Fan 2 is OK, speed is 7258 RPM