Environmental requirements

Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions beyond those for which it was tested. The ranges specified in Table 25 list the acceptable environment for both operating and non-operating conditions.

Table 25 Environmental requirements

Condition

Acceptable range during operation

Acceptable range during

 

 

 

non-operation

 

 

 

Ambient

0° to 40° Celsius (32° to 104°

-25° to 70° Celsius (-13° to 158°

temperature

Fahrenheit)

 

Fahrenheit)

 

 

 

Humidity

10% to 85% RH non-condensing, at

10% to 90% RH non-condensing, at

 

40° Celsius (104° Fahrenheit) , with

70° Celsius (158° Fahrenheit)

 

maximum gradient of 10% per hour

 

 

 

 

Altitude

3,000 meters (9,842 feet) above sea

0 to 12 kilometers (39,370 feet) above

 

level

 

sea level

 

 

 

Shock

20 G, 6 ms duration, half-sine wave

Half sine, 33G 11ms, 3/eg Axis

 

 

 

Vibration

0.5 G sine, 0.4 grms random, 5-500 Hz

2.0 G sine, 1.1 grms random 5-500

 

 

 

Hz

Airflow for 4/32

24 cubic ft/minute

None required

SAN Switch

 

 

 

 

 

 

Airflow for 4/8,

47 cubic ft/minute

None required

4/16, and 4/64

 

 

 

SAN Switches

 

 

 

 

 

 

 

Airflow for 4/32B

High speed,

9300 RPM,

None required

SAN Switch

20.8 cubic

feet/ minute

 

 

Low speed, 7200 RPM, 15.4 cubic feet/

 

 

minute

 

 

Table 25 Environmental requirements NOTE:

The –10 ºC to +40 ºC range applies to the ambient air temperature at the air intake vents on the nonport side of the switch. The temperature inside the switch can be up to 75 ºC during switch operation.

If the internal temperature range exceeds the operating ranges of the components, the LEDs, error messages, and Fabric Watch alerts will indicate a problem. Issue the tempshow command to view temperature status.