Example 3:

switch:admin> tsclockserver

LOCL

switch:admin> tsclockserver 132.163.135.131 switch:admin>

Set the time zone

To set the time zone:

1.Log in as admin.

2.Issue the following tstimezone command: tstimezone[houroffset] [minuteoffset]

For Pacific Standard Time, enter tstimezone –8,0.

For Mountain Standard Time, enter tstimezone –7,0.

For Central Standard Time, enter tstimezone –6,0.

For Eastern Standard Time, enter tstimezone –5,0.

The default time zone for switches is Universal Time Conversion (UTC), which is eight hours ahead of Pacific Standard Time. The parameters listed do not apply if the time zone of the switches has already been changed from the default (eight hours ahead of PST).

See the tstimezone command in the Fabric OS command reference manual for more detailed information about the command parameters.

3.Repeat step 1 and step 2 on all switches for which the time zone needs to be set. The time zone is set only once; the value is stored in nonvolatile memory.

For U.S. time zones, Table 6 on page 63 provides the correct offset parameters for the tstimezone command.