MD566X
 Revision History
 Symbol Units of measure
Conventions
Programmer’s Guide
Acronym Definition
 Dram
 Chipset Contents Qty
Introduction
Intel V.90/V.92 56K Chipsets
 V.92, V.90 and V.34 Data Modes
Modem Connection Overview
 DTE-to-DCE Data Rates for Each Mode
DCE-to-DCE Data Rates for Each Mode
Mode Data Rate bps Affected Data
 AT Command Summary Tables
Data Mode Command Summary
Command Function Default Range Reported by
 Intel Confidential
 Data rate Result code type Yes
 Ports only Async mode
 +GMI?
 Intel Confidential
 V.44 / V.42 / V.42 bis MNP∗ Command Summary
Command Function Default Range Reported By &Vn
 Intel Confidential
 Value saved in Nvram
 Fax Identity Command Summary
Fax Class 1 Command Summary
IS-101 Voice Command Summary
 Voice DTE→DCE Character Pairs
Response Hex Code Function
 Voice DTE←DCE Character Pairs
 Dial Modifiers Command Function
Register Function Default Range Units Reported By &Vn
S-Register Summary
 10. V.90/V.92 Mode DCE-to-ISP Response Codes
Verbose Code Numeric Code
 11. V.34 Mode DCE-to-DCE Response Codes
12. DTE-to-DCE Data Rate Response Codes
 13. Manufacturing-Only Command Summary a
Command Function Default Range
 Basic Data Mode AT Commands
Using AT Commands to Access the S-Registers Sn?, Sn=x, ?
Modem Responses and Command Echo En, Vn, Xn, Wn, Qn
Modem Setup Host Command Modem Response
 Example of a Remote Connection
 Product Identification Information
Information
 Establishing a Modem Connection A, D, DS = n, S0
 Online Command Mode Escape Codes, On
Hanging Up Hn, S10, Zn, &D2
Modem-to-Modem Connection Data Rates
 Intel Confidential
 Intel Confidential
 ATH +PMHF
 +PMHR
 Supported Modulation Types
Carrier Description
 +MS = carrier , automode, min rate, max rate
S37
 Originating Answering Resulting Connection Speed Modem
Figured to attempt only a 28,800 bps connec
 Diagnostic Testing S18, &Tn
Local Analog Loopback AT&T1
 AT&T0
 Local Analog Loopback With Self-Test AT&T8
Local Analog Loopback with Self-Test
 AT Escape Sequences
Licensing Requirements for Hayes Escape Sequence
Time-Independent Escape Sequence
 Hayes∗ Escape Sequence
 Data Mode Command Descriptions
Command Default Description
None
 Stant carrier mode
 Dialing Digits
 Online data mode echo
 Reports product code
 Cont
ATI5
 Mode from online command mode
 Sn=x
Sn?
 Protocol Lapm
 Sequent commands to be ignored
 For data mode
 Ports asynchronous mode. This command is the same as &M0
 User profile n
 Modem power-up
Zn=x None
 +GMR?
 +MS=m See m
V34BS
 Modulation Selection
Cont
 Examples DTE data rate = 115,200 bps
+MS=m
Examples DTE data rate = 2400 bps
 +PCW=m
+PMH=m
 +PMHR none
DCE
 +PSS=m
Mand
 Intel Confidential
 Error Correction and Data Compression
Mode Features
 Resulting \Nn Connection Types
 Bis with fallback to MNP5 \N3
 \An
\Bn None
 \Cn
\Gn
\Jn
 \Kn
\Nn
 \Qn
\Tn
\Xn
 Intel Confidential
 0,471
+DS44=m 972,140
140,1884 3768
 FAX Class 1 AT Commands
Fax Identity Commands
Fax Identity Command Descriptions
Tocols
 Fax Class 1 Commands
+FREV?/+FMR? none
 Mod Selection Table
Value Modulation Speed Bps
 Class 1 DTE-Generated Hdlc Frame Information AT+FTH=mod
 Fax Mode Command Descriptions
+FCLASS=1
 Command Default Description Receive Hdlc Data
+FRH=n
+FRM=n None
+FRS=n None
 DTE after receiving the +FTH=mod command
 Data using the modulation selected in mod
 IS-101 Voice Mode AT Commands
Each command may be used as follows
 Dtmf Detection
Relay Control
 Voice Mode Command Descriptions
+FLO=n
 +VBT=m
+VCID=n
 Enable Report Function
+VDR=m
+VEM=m See m
 +VEM=m
Dialtone
 Example 2. Setting the Event Mask
Example 3. Reading the Event Mask Settings
Event Reporting and Masking
Example 1. Viewing Supported Events
 +VGM=n 128
+VGR=n 128
+VGS=n
+VGT=n
 +VIP none
 Code
+VLS=n
 Relay/Playback Control
Primitive Code +VLS=n
+VNH=n
 Intel Confidential
 +VRX none
 = sds, sdi Defaults m = 128
+VSD=m See ‘m’
 Manufac +VSM=m turer- specified
Vsr Comments Samples/second
 Compression Method Selection
+VSM=m Manufac
Vsr
Hard Disk
 +VSP=n
+VTD=n 100
 +VTS=m none
 Dtmf and Tone Generation
AT+VTS=DTMF or
 AT+VTS= , ,duration For example AT+VTS= , ,50
 Intel Confidential
 S-Register Command Descriptions
Registers
 Ascii decimal
 S10
S11
S12
 S14 138
S16
 S21
S22 118
 S23 None
S27
 S31
 S33
 Maximum Line Speed Attempted
 110
 Caller ID
Caller ID Tags for Formatted Reporting
 Ring
 MANUFACTURING-ONLY Commands
Manufacturing-Only Command Descriptions
NCnn
 S91
S92
 $TTnn
 Tone Test Command Analog Loopback ALB Test
FAX Test
 Command Bit Pins
#VGP0=n
#VGP1=n See Note
#VGP2=n
 118
 Parallel Host Interface 16C450/16C550A Uart
Programmer’s Guide
119
 Parallel Host Interface Uart Register Bit Assignments
Register BIT Number Address Name
 Uart Register Definitions
Scratch Register SCR
Modem Status Register MSR
Line Status Register LSR
 Are no subsequent Fifo errors
Modem Control Register MCR
 Line Control Register LCR
123
 Fifo Control Register FCR
Trigger Level Bytes
 Interrupt Identity Register IIR
Interrupt Control Functions
125
 Interrupt Enable Register IER
Transmitter Holding Register THR
10.1.10Receiver Buffer Register RBR
 Fifo Interrupt Mode Operation
10.2 16C550A Uart Fifo Operation
10.1.11Divisor Latch Registers DLM and DLL
Programmable Data Rates
 Fifo Polled Mode Operation
 129
 130