Intelligent Motion Systems MDriveAC manual Setup Parameters

Models: MDriveAC

1 79
Download 79 pages 41.28 Kb
Page 22
Image 22

Setup Parameters

The following table illustrates the setup parameters. These are easily configured using the IMS SPI Motor Interface configuration utility. An optional Parameter Setup Cable is available and recommended with the first order.

MDriveAC Plus Microstepping Setup Parameters

Name

Function

Range

Units

Default

 

 

 

 

 

MHC

Motor Hold Current

0 to 100

percent

5

 

 

 

 

 

MRC

Motor Run Current

1 to 100

percent

25

 

 

 

 

 

 

 

1, 2, 4, 5, 8, 10, 16, 25, 32, 50,

µsteps per

 

MSEL

Microstep Resolution

64, 100,108, 125, 127,128,

256

full step

 

 

180, 200, 250, 256

 

 

 

 

 

DIR

Motor Direction Override

0/1

CW

 

 

 

 

 

HCDT

Hold Current Delay Time

0 or 2-65535

mSec

500

 

 

 

 

 

CLK TYPE

Clock Type

Step/Dir. Quadrature, Up/Down

Step/Dir

 

 

 

 

 

CLK IOF

Clock and Direction Filter

50 nS to 12.9 µS

nS (MHz)

200 nS

(10 MHz to 38.8 kHz)

(2.5 MHz)

 

 

 

USER ID

User ID

1-3 characters

Viewable ASCII

IMS

 

 

 

 

 

WARN TEMP

Warning Temperature

0 to 125

Degrees

80

Celsius

 

 

 

 

EN ACT

Enable Active State

High/Low

High

 

 

 

 

 

Table 1.4.1: Setup Parameters

1-16

MDriveAC Plus Microstepping Hardware - Revision R121707

 

Relevant to Firmware Version 3.0.02

Page 22
Image 22
Intelligent Motion Systems MDriveAC manual Setup Parameters