IMS Part Number/Serial Number Screen
The IMS Part Number and Serial Number screen is accessed by clicking "View > Part and Serial Numbers".
This screen is
IMS Part #
IMS Serial Number
Figure 2.3.9: SPI Motor Interface Part and Serial Number Screen
Fault Indication
All of the IMS SPI Motor Interface Screens have the Fault field visible. This
MDriveAC Plus Microstepping Fault Codes
Binary | Error | Description | Action | To Clear | |
Case* | Code |
|
|
| |
— | None | No Fault | — | — | |
4 | CS | SPI Checksum Error | Error | Write to MFM | |
Displayed | (Set Button) | ||||
|
|
| |||
8 | SC/CS | SPI Checksum Error/ | Error | Write to MFM | |
Sector Changing | Displayed | (Set Button) | |||
|
| ||||
16 | DFLT | Defaults Checksum | Error | Write to MFM | |
Error | Displayed | (Set Button) | |||
|
| ||||
32 | DATA | Settings Checksum | Error | Write to MFM | |
Error | Displayed | (Set Button) | |||
|
| ||||
64 | TW | Temperature Warning | Error | Write to MFM | |
Displayed | (Set Button) | ||||
|
|
|
*All Fault Codes are OR'ed together
Table 2.3.5: MDriveAC Plus Microstepping Fault Codes
MDriveAC Plus Microstepping Hardware - Revision R121707 | |
| Relevant to Firmware Version 3.0.02 |