Switch Interface Example

Switch Interface

(Sinking)

+5 to +24VDC

GND +

SPST

Switch

Optocoupler Reference

MDriveACPlus Microstepping

Enable Input

Switch Interface

(Sourcing)

+5 to +24VDC

GND +

SPST

Switch

Optocoupler Reference

MDriveACPlus Microstepping

Enablle IInputt

Figure 2.1.6: Switch Interface Example

Fault (Temperature Warning) Output

The MDriveAC Plus Microstepping features an Open-Drain Fault output located at Pin 19 of connector P1. This is an impending over-temperature and over-temperature fault.

When the internal temperature of the MDriveAC Plus reaches the temperature specified by the WARN_TEMP parameter, the output will pulse at 1 second intervals (1/2 second on, 1/2 second off). When an over-temperature fault state is reached the output will latch on.

The output will remain in the latched condition until a power cycle, or new parameter set from the IMS SPI Mo- tor Interface.

 

 

Fault Output

 

 

Input Type

 

Open Drain

 

 

 

 

 

 

 

Drain-Source Voltage

 

+5 to +24 VDC

 

 

Drain Current

 

50 mA

 

 

 

 

 

 

Table 2.1.3: Fault Output Specifications

2-8

 

MDriveAC Plus Microstepping Hardware - Revision R121707

 

 

 

Relevant to Firmware Version 3.0.02

Page 35
Image 35
Intelligent Motion Systems MDriveAC manual Fault Temperature Warning Output, Switch Interface Example