Jenn-Air SEG196 manual To adjust tl c lAD settling

Models: SEG196

1 51
Download 51 pages 45.47 Kb
Page 11
Image 11
To adjust tl_c lAD settling:

To adjust tl_c lAD settling:

1. Light burner and set control knob for low flame.

2.Remove control knob from valve stem.

CAUTION:

Never use a metal blade to pry knob off. If knob cannot be easily removed, tuck the folds of a cloth dishtowel under the knob skirt and pull the towel upward with steady, even pressure.

3.Insert a slender, thin-blade screwdriver

into the recess

at

center

of

valve

stem

 

TOINCREASEFLAME

and engage

blade

with slot

in adjusting

_/_

SJZE

 

 

 

 

 

 

 

COUNTERCLOCKWISE

screw.

 

 

 

 

 

 

CLOCKWISE

 

 

 

 

 

 

 

 

TO REDUCE

 

4. Turn center stem adjusting

screw slightly

FLAMES_ZE

 

tO set flame size. Note: Turn clockwise

 

 

to reduce or

counterclockwise

to in-

 

 

crease flame

size.

 

 

 

 

VALVE

 

 

 

 

 

 

 

 

 

5. Replace control

knob when

adjustment

STEM--

 

is completed.

Proper adjustment will produce a stable, steady blue flame of minimum size. The final adjustment should be checked by turning knob from Hi to Lo several times without extinguishing the flame.

This adjustment, at the Lo setting, will automatically provide the proper flame size at Meal setting.

11

Page 11
Image 11
Jenn-Air SEG196 manual To adjust tl c lAD settling