Check the followinglistto be sure a service call is really necessary. A quick reference of this manual may prevent an unneeded service call.

If grill or surface burner fails to light:

check 10be sure unitis properlyconnectedto powersupply.

check for a blowncircuitfuse or a trippedmain circuitbreaker.

check to be sure burnerportsor ignitionportsare not clogged.

checkto be sure igniterisclicking. If igniterdoesn'tclick,turncontrolknobOff and

clean iginitor. (See p. 46.)

s check to be sure appliance regulator is set for correct fuel. (See installation instructions.)

checkto be sure inletpressureis adequate. (Call gas company.)

if the flame is uneven:

burner ports may be clogged.

flame settingmay need to be adjusted. (See p. 13.)

If grill or surface burner flame lifts off the ports:

shutteronthe mixertube needsto be closeduntilflamesettleson the burnerports. (See pp. 12-13.)

If grill or surface burner flame is yellow in color:

shutteron the mixertube needsto be openeduntilyellow disappears. (See pp. 12- 13)

If nothing on the range operates:

checkfor a blown circuitfuse or a tripped main circuitbreaker.

check if range is properlyconnectedto electric circuitin house.

If ventilation fan does not operate but everything else on the range does:

check behind lower access panel if power cord to blower assembly has been disconnected.

If ventilation system is not capturing smoke efficiently:

check on crossventilation in room or make up air.

excessive amount of smoke is being created; check instructions for grilling,

trimming meats. (See pp. 18-20.)

soutside wall cap may be trapped shut.

range may be improperly installed; check ducting information. (See p. 9.)

air filter may be improperly installed (See p. 10.)

50

Page 50
Image 50
Jenn-Air SVD48600 manual If ventilation system is not capturing smoke efficiently