Fan Modules

FAN MODULES

The NetScreen-5200 has a three-fan module and the NetScreen-5400 has a two-fan module. You can access the fan module from the left front side of each chassis.

To remove the NetScreen-5200 fan module, turn the fan knob in the unlock position, then gently pull the fan module lever toward you to slide the module out.

To remove the NetScreen-5400 fan module, loosen the two thumb screws that secure the fan module, then gently slide the module out.

If a fan stops operating due to failure or removal, then the system continues to run and generates an alarm. When you replace the fan, do not leave the fan tray empty for more than two minutes. See “Replacing the Fan Module” on page 37 for more information.

NETSCREEN-5000 MODULES

The NetScreen-5000 Series systems support two module types:

NetScreen-5000 management modules

NetScreen-5000 Secure Port Modules (SPMs)

The following table shows the modules supported by each slot.

 

slot 1

slot 2

slot 3

slot 4

 

 

 

 

 

NetScreen-5200

Management

Secure Port

N/A

N/A

 

Module

Module

 

 

 

 

 

 

 

NetScreen-5400

Management

Secure Port

Secure Port

Secure Port

 

Module

Module

Module

Module

 

 

 

 

 

The following table shows the configurations for each Management Modules and Secure Port Module and shows if the firmware version is included on the Management Module or needs to be downloaded.

 

Configuration 1

Configuration 2

Configuration 3

 

 

 

 

Management Module

5000-MGT

5000-MGT2

5000-MGT2

 

 

 

 

Secure Port Module

5000-8G and/or

5000-8G and/or

5000-8G2 and/or

 

5000-2G24FE

5000-2G24FE

5000-2XGE

 

 

 

 

Software Version

Software is installed on

Software is installed on

Must download from the

 

the shipping

the shipping

support site.

 

management module.

management module

www.juniper.net/

 

 

 

support

 

 

 

 

NetScreen-5000 Series