8. PLAYBACK MODE

8-2 Fast-Forward, Rewind

9. TIME CODE OPERATION

The GY-DV550 records SMPTE-standard (U MODEL)/EBU-standard (E MODEL) time codes and user's bits. In the play or record mode, the reproduced time codes or user's bits are shown on the counter display. The LTC signal from the built-in time code generator is output through the TC OUT connector. In the play mode, the time code recorded on the tape is not output through the units connectors.

Do not directly turn off the POWER switch in the record-pause mode; otherwise, time codes will not continue. Be absolutely sure to turn off the OPERATE switch beforehand.

REW button FF button

9-1 Displaying Time Code

ALARM

MONITOR

 

GAIN OUTPUT

WHT.BAL

VTR

 

NG OPERATE

Press the FF button in stop mode to fast forward the tape. Press the REW button in stop mode to rewind the tape.

Press the STOP button to stop fast forwarding or rewinding.

8-3 Search

LOG REW STOP FF PLAY STILL

STOP button

When the tape approaches the end during fast forwarding or rewinding, the tape speed decelerates to protect the tape.

The time required for fast forwarding and rewinding may become longer when used in a cold environment. This is not a malfunction.

OPERATE/WARNING

LIGHT

RESET

CH 1

 

 

 

OVER

AUTO OFF

DEW

ON

 

MODE

 

CH 2

40 30

20

10

0 dB

SERVO RF

L i

OFF

 

RM

 

 

 

 

OVER

 

VTR

MONITOR

32k

48k

 

SLAVE

PB

NDF

HOLD

 

 

 

AUD LOCK

SP

 

 

 

 

 

 

COUNTER

 

INCOM

SELECT

MENU

WIDE

 

H

M

S

 

F

 

MIC

CH-1

REMAIN

 

 

REV FWD E

BATT F

CTL

CARBON

MIX

 

 

TC

CH-2

 

 

H

M

 

 

 

UB

DYNAMIC

 

 

 

 

 

 

 

 

 

 

INCOM

 

 

 

 

 

 

 

 

 

 

 

MIC

LEVEL

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

CH-1

CH-2

 

CH-1

CH-2

 

 

 

 

 

 

 

AUTO

 

 

FRONT

 

 

 

 

 

 

 

MANUAL

 

 

REAR

 

 

 

 

 

 

 

AUDIO SELECT

 

AUDIO INPUT

OFF

 

 

 

 

 

 

 

 

 

 

 

 

CH-1 AUDIO CH-2

 

 

 

 

 

 

 

CALL

 

LEVEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RM

OFF DC IN

 

 

 

 

 

 

 

 

 

 

 

/BATT.

POWER

Hour

Min.

Sec.

Frame

 

H

M

 

S

 

F

 

 

 

Time code display

 

 

 

 

 

User’s bit display

 

 

 

 

 

COUNTER switch

 

 

 

 

 

The selected time codes can be shown on the counter display

during playback and recording as follows.

 

 

Set the VCR Setup Menu item No. 516 DISPLAY SELECT to “TC”.

See page 75.

Set the COUNTER switch to "TC" or "UB". TC: Time codes are displayed.

UB: User's bit data of time codes are displayed.

REW button FF button

9-2 Presetting and Recording of Time Code

ALARM

MONITOR

 

GAIN OUTPUT

WHT.BAL

VTR

 

NG OPERATE

LOG REW STOP FF PLAY STILL

STOP button PLAY button

The time code or user's bit data to be recorded onto

 

 

TC GENE Switch

 

CH-1

AUDIO

CH-2

 

 

 

 

LEVEL

 

 

 

 

 

CH-1

CH-2

 

CH-1

CH-2

 

 

 

 

 

 

AUTO

 

FRONT

 

 

 

MANUAL

 

REAR

 

 

 

AUDIO SELECT

 

AUDIO INPUT

 

 

VTR SELECT TC GENE.

 

MENU

SEE

 

INT

 

CONTINUE

INSTR-

 

PRST

REC

 

 

UCTION

 

PARA

FREE

 

 

MANUAL

 

EXT

REGEN

 

 

 

 

LITHIUM BATT.

CAM AUX

GROUP

ITEM

SELECT

DATA SET

 

 

HOLD

SHIFT

ADVANCE

PRESET

 

 

 

the tape can be preset to a desired value.

NON DROP : The time code generator's running method is set to the non drop frame mode. Use this setting when placing emphasis on the number of frames. In the NON DROP frame mode, the "NDF" indicator lights on the display.

NDF

VTR INPUT

Press the FF button in play mode to search the tape in the forward direction at about 10 times the normal speed.

Press the REW button in play mode to search the tape in the reverse direction at about 10 times the normal speed.

Press the PLAY button to resume normal playback.

Press the STOP button to stop.

The audio is reproduced during the search.

Video noise may be observed or the image may become

unstable during the search, but this is not a malfunction.

Setting the time code related switches

Set the TC GENE switch to REC or FREE.

REC : The data preset in the time code generator runs only during recording.

Use this setting if it is required to record continual time codes across different scenes.

*However, approximately ±1-frame variations may occur in scene transition accuracy.

FREE : The time code starts to run from the time it is preset in the time code generator.

Setting the VCR Setup Menu (U MODEL)

Set the VCR Setup Menu item No. 516 DISPLAY SELECT to “TC”.

Select the time code generator's framing mode using the VCR

Setup Menu item No. 416 NON DROP/DROP.

DROP

: The time code generator's running method is set

 

to the drop frame mode.

 

Use this setting when placing emphasis on the

 

recording time.

 

The “DF” indicator lights up on the display in the

 

drop-frame mode.

H

M

S

F

Drop frame/Non-drop frame mode (U MODEL)

 

In the NTSC system, the actual number of frames per 1

second is approximately 29.97 frames, but the number of

frames that becomes the processing reference of the time

code is 30 frames. To compensate for this difference, the

mode called drop mode drops frame 00 and 01 for every

minute that cannot be divided by 10.

 

 

The non-drop frame mode is when no frames are dropped

and the actual time shift is neglected.

 

 

Note:

 

 

 

When the VCR Setup Menu item No. 398 SSF MODE is set

to CUE MODE or MARK MODE, the time code generator’s

running method is internally set to the REGEN mode.

When this is the case and you want to enter the preset

mode, set the VCR Setup Menu item No. 398 SSF MODE

to “OFF”, or set the TC GENE switch to the REC or FREE

position again.

 

 

 

61

62

Page 32