12. SETUP MENU
| VCR Setup Menu (Cont'd) |
12. SETUP MENU
12-2 Camera Menu Screen Flow
Group
Item | Setting | |
Value | ||
| ||
Upper row: Viewfinder display |
Contents | Factory | |
Setting | ||
|
Camera Menu Screen Flow As illustrated below, the Camera Menu is a menu screen comprising several layers. The first layer of the CAMERA MENU screen is for choosing and setting the menus required in accordance with functions or purposes. The unit also allows the contents of menu settings to be stored in three files (SCENE FILE A, B, OFF).
SYSTEM
Lower row: Counter display indication | |
302: BACK SPACE | STANDARD |
| QUICK |
St | |
| qU |
Selection of amount of back space for recording pause. | STAND- | |
STANDARD : Normally use this setting. | ARD | |
QUICK | : Compared to STANDARD, the back space |
|
| becomes approximately 0.4 seconds shorter. |
|
| Use this setting when you want to start |
|
| shooting quickly. However, in the REGEN |
|
| mode, the time code may not continue. |
|
• SCENE FILE A, B |
By performing the FILE STORE operation on |
the FILE MANAGE screen, the contents of |
menu settings can be stored and retained in |
the unit. However, the SET UP menu |
contents are stored even if the FILE STORE |
operation is not performed. |
Use SCENE FILE A or B to store and retain |
- - - VF | D I SP LAY - - - |
SCENE | F I LE A |
F . NO / F I L TER | : OFF |
307:LONG PAUSE TIME
LGPt
396:BATTERY TYPE
bAtt
3MIN | To select the time (minutes) before the tape protect mode (drum head rotation | |
30MIN | stopped) is engaged when the | |
03 | 3MIN | : 3 minutes |
30MIN | : 30 minutes |
30* When used in a cold environment, the setting will be 3 minutes regardless of the setting.
12V | To be set in accordance with the used battery back type. | |
13.2V | 12V | : Choose this setting when using 12V battery |
14.4V |
| (12V DC Flat shape type). |
| 13.2V | : Choose this setting when using 13.2V battery |
12
13Magnum 13, Compack 13).
1414.4V : Choose this setting when using 14.4V battery
Note: |
30MIN
12V
the contents of menu settings that remain |
more or less fixed. |
• SCENE FILE OFF |
Whenever you want to change the menu |
settings, use this SCENE FILE. |
The menu setting contents are stored in the |
unit even if the FILE STORE operation is not |
performed. |
When shooting, select the file with the menu settings |
to be used from among the three SCENE FILE files |
on the CAMERA MENU screen. |
Cursor |
AUD I O D I SPLAY | : OFF | |||
SAFETY | ZONE |
| : NORMAL | |
CENTER MARK |
| : ON | ||
REC | T I ME |
| : REMA I N | |
ZEBRA |
|
| : 7 0 - 8 0% | |
PAGE BACK |
|
| ||
| - - - OPERAT I ON - - - | |||
| SCENE | F I LE | A | |
ASPECT | RAT I O |
| : 4 : 3 | |
SHUT TER |
|
| : STEP | |
FAW |
|
|
| : NONE |
GA I N | L |
|
| : 0 dB |
GA I N | M |
|
| : 9 d B |
GA I N | H |
|
| : 1 8 dB |
SMOOTH | TRANS |
| : OFF | |
SPOT | L / BACK | L | : M I DDLE | |
PAGE BACK |
|
|
CAUTION: When controlling the unit with the camera remote control unit, REMOVE will appear in the setting value section. In this case, menu settings cannot be made.
• | If this setting is neglected, the unit’s display of remaining of battery |
| power and generation of battery alarm will not work correctly. |
•This setting is valid when battery pack is used. It
is invalid when a DC power supply is used.
- - - CAMERA MENU - - - | |
SCENE F I L E | : A |
VF D I SP L AY | MENU . . |
OPERAT I ON MENU . .
PROCESS MENU . .
| - - - PROCESS | - - - | - - - ADVANCED PROCESS - - - | ||
SCENE | F I LE A |
| SCENE F I L E | A | |
MASTER | BLACK |
| : NORMAL | COLOR MATR I X | : ON |
DETA I L |
|
| : NORMAL | GAMMA | : NORMA L |
DT L . V / H | BAL |
| : NORMAL | SK I N COLOR ADJUST . . |
|
398:SSF MODE
SSF
OFF CUE MODE MARK MODE
oF cU nr
Selection of the S.S.F. (Super Scene Finder) mode. | |
S.S.F. function:While recording, the time code data of a | |
desired recorded scene is stored in the unit's memory | |
when the TAKE button on the front section is pressed. | |
Settings cannot be changed during recording or SAVE mode. | |
OFF | : S.S.F. function is not available. |
CUE MODE | : Selects the CUE mode. |
| When the TAKE button is pressed, the time code data of |
| the scene recorded at that point is stored in the memory. |
MARK MODE : Selects the MARK mode. | |
| When the TAKE button is pressed the first time, the time |
| code of this point is stored as start point of the scene. When |
| the TAKE button is pressed the second time, the time code |
| of this point is stored as ending point of the scene. |
For details on the S.S.F. function, see page 66. |
OFF
F I L E MANAGE . . SETUP MENU . .
T I ME DATE MENU . . EX I T
Normal screen
DT L . FREQUENCY | : M I DDLE | PAGE BACK | ||
SK I N | DT L DETECT | : OF F |
| |
V RESOLUT I ON | : NORMAL |
| ||
KNEE | PO I NT | : 1 0 0% |
| |
ADVANCED | PROCESS . . |
| ||
PAGE BACK |
|
|
| |
| - - - | F I LE MANAGE - - - |
| |
| SCENE F I LE | A |
| |
STORE | F I LE | : A |
| |
STORE |
|
|
|
|
RESET | F I LE | : OFF |
| |
RESET |
|
|
|
|
PAGE BACK
STORE OK?
TIME CODE
399: | REMOTE FF/REW |
| MODE |
rEFF |
|
403:
UbSc
FF/REW SEARCH
FF SH
TC&UB TC
on oF
•When the VCR Setup Menu item No. 398 S.S.F. MODE is set to CUE or MARK, the time code generator’s running method is internally set to the REGEN mode.
Specifies the operation when FF/REW signal is received | |
from the remote connector during playback. | |
FF/REW : FF/REW operation performed. | |
SEARCH : Search operation performed. | |
To set whether user’s bits also should be | |
when | |
TC&UB : User’s bits also | |
TC | : User’s bits are not |
FF/ REW
TC
|
| - - - SETUP - - - |
| |
2 6P I N | OUT | : CPN | ||
CHARACTER M I X | : OFF | |||
SET UP | : ON (U MODEL) | |||
H | PHASE | : | 1 2 8 | |
SC | COARSE | : | 0 | |
SC | F I NE | : | 1 2 8 | |
PAGE BACK |
|
| ||
|
| - - - T I ME | DATE | - - - |
D I SPLAY | : ON | |||
D I SPLAY MODE | : BARS+CAM | |||
D I SP | STYLE | : DATE&T I ME | ||
DATE | STYLE | : MM/ DD / YY |
- - SK I N COLOR AD J UST - -
| ERORR |
|
SK I N COLOR DET . | STOP | |
SK I N | COLOR RANGE | : NORMA L |
PAGE | BACK |
|
ON SCREEN
416:NON DROP/ DROP (U MODEL)
tcG |
|
516: | DISPLAY SELECT |
diSP |
|
DROP NON DROP
dF nF
TC CLOCK
tc cL
Selection of the time code generator's framing mode as | |
either drop or | |
DROP | : The internal time code generator runs in drop mode. |
| Choose this setting when emphasizing the recorded time. |
NON DROP: The internal time code generator runs in non drop mode. | |
| Choose this setting when emphasizing the frame number. |
Selection of the appearance of the counter display when | |
the COUNTER switch is set to “TC” or “UB”. | |
TC | : The time code is displayed. |
CLOCK: The date/time is displayed. |
DROP
TC
T I ME | STYLE | : 2 4HOUR |
SEC | D I SPLAY | : OFF |
PAGE BACK
75 | 76 |