| 12. SETUP MENU |
| OPERATION Screen |
|
Item | Function, Operation | Variation Range Initial Setting |
12. SETUP MENU |
| |
| PROCESS Screen |
|
Item | Function, Operation | Variation Range Initial Setting |
ASPECT RATIO
SHUTTER
FAW
GAIN L
GAIN M
GAIN H
SMOOTH
TRANS
SPOT L/
BACK L
PAGE BACK
Sets the image size of the video signal. | LETTER | 4:3 | ||||
LETTER | ...... | LETTER BOX (16:9 aspect ratio) image output. | 4:3 |
| ||
4:3 |
|
| 4:3 aspect ratio image output. |
|
| |
|
|
|
|
| ||
| Note: |
|
|
|
| |
When setting ASPECT RATIO to LETTER, 16:9 screen detection ID |
|
| ||||
signal will not be outputted from the Y/C OUT connector. |
|
| ||||
The SHUTTER button on the right side section is used to select STEP for | STEP | STEP | ||||
fixed shutter speed or V.SCAN variable scanning rate for shooting computer | VARIABLE |
| ||||
monitor screens. |
|
| ||||
STEP |
| Enables setting of different fixed shutter speeds. [1/100, |
|
| ||
|
|
|
| 1/250, 1/500, 1/1000, 1/2000] (U MODEL) |
|
|
|
|
|
| [1/120, 1/250, 1/500, 1/1000,1/2000] (E MODEL) |
|
|
VARIABLE | ....... Selected when shooting computer monitor screens, etc. |
|
| |||
|
|
|
| [Variable range: 60.1 to 2084.6 Hz] (U MODEL) |
|
|
|
|
|
| [Variable range: 50.1 to 2067.8 Hz] (E MODEL) |
|
|
Selects the W.BAL switch (@ on page 13) position to which the FAW (Full- | NONE | NONE | ||||
Time Auto White Balance Adjustment) function is to be assigned. | A |
| ||||
NONE |
| FAW function is not used. | B |
| ||
A |
| FAW is assigned to the A position. | PRESET |
| ||
B |
| FAW is assigned to the B position. |
|
| ||
PRESET | ......... | FAW is assigned to the PRESET position. |
|
| ||
Selects the gain value in each position of the GAIN switch (9 on page | L: 0dB | |||||
13). |
|
|
|
| 0dB | M: 9dB |
|
|
|
|
| 3dB | H: 18dB |
|
|
|
|
| 6dB |
|
|
|
|
|
| 9dB |
|
|
|
|
|
| 12dB |
|
|
|
|
|
| 18dB |
|
|
|
|
|
| ALC |
|
Smoothens the transition when the GAIN switch (9 on page 13), or | ON | OFF | ||||
WHT.BAL switch (@ on page 13) is switched over and achieves gradual | OFF |
| ||||
change in place of sudden change. |
|
| ||||
However, the smooth transition function does not function when switching |
|
| ||||
the GAIN switch set in ALC, FAS button and the LOLUX button. |
|
| ||||
ON |
| Activates the smooth transition function. |
|
| ||
OFF |
| Deactivates the smooth transition function. |
|
| ||
Sets the level of auto iris when setting the AUTO IRIS switch to BACK L or | LOW | MIDDLE | ||||
SPOT L. |
|
|
| MIDDLE |
| |
LOW | : Lowers the iris level. | HIGH |
| |||
MIDDLE | : Opens/Closes the iris by 1 step from the standard state. |
|
| |||
HIGH | : Raises the iris level. |
|
| |||
The CAMERA MENU returns when the SHUTTER dial is pressed with | – | – | ||||
the cursor at this position. |
|
|
MASTER | Adjusts the pedestal level (master black), which is the reference of black. | MAX (100) | NORMAL | |||
BLACK | • To increase the pedestal level | Increase the number. (UP) | 99 | 201 |
| |
| • To decrease the pedestal level .... | Decrease the number. (DOWN) |
| gradations |
| |
|
|
|
| to |
|
|
|
|
|
| NORMAL (0) |
| |
|
|
|
| to |
|
|
|
|
|
|
|
| |
|
|
|
| MIN |
| |
DETAIL | Adjusts the detail enhancement level. | MAX (7) | NORMAL | |||
| • To sharpen details | Increase the number. (UP) | 6 | 15 |
| |
| • To soften details | Decrease the number. (DOWN) |
| gradations |
| |
|
|
|
| to |
|
|
|
|
|
| NORMAL (0) |
| |
|
|
|
| to |
|
|
|
|
|
|
|
| |
|
|
|
| MIN |
| |
DTL. V/H | Sets the direction, horizontal (H) or vertical (V), in which stronger detail | NORMAL | ||||
BAL | enhancement is applied. |
| 3 | 9 |
| |
| To strengthen the H enhancement ... | .. Increase the number (UP). |
| gradations |
| |
| To strengthen the V enhancement ... | .. Decrease the number (DOWN). | to |
|
| |
| Note: |
|
| NORMAL (0) |
| |
|
|
| to |
|
| |
| While the LOLUX function is operating, the setting value is fixed at |
|
| |||
|
|
| ||||
| NORMAL and “FIX” is displayed. |
|
|
| ||
|
|
| ||||
|
|
|
|
| ||
DTL. | Varies the detail enhancement level by changing the detail enhancement | HIGH | LOW | |||
FREQUENCY | frequency. Set in accordance with the subject | MIDDLE |
| |||
| HIGH | Applies strong detail enhancement. | LOW |
| ||
|
| Used to shoot subjects with fine patterns. |
|
|
| |
| MIDDLE | Applies medium detail enhancement. |
|
|
| |
| LOW | Applies weak detail enhancement. |
|
|
| |
| Note: | Used to shoot subjects with large patterns. |
|
|
| |
|
|
|
|
|
| |
| While the LOLUX function is operating, the setting value is fixed at |
|
|
| ||
| MIDDLE and “FIX” is displayed. |
|
|
|
| |
SKIN DTL | Sets the Skin Detail function to ON or OFF. | ON |
| OFF | ||
DETECT | ON | Skin Detail function activated. | OFF |
| ||
| OFF | Skin Detail function not activated. |
|
|
|
☞See "Using the Skin Detail Function" on page 91.
V. | Increases the vertical resolution. | NORMAL | NORMAL | |
RESOLUTION | • NORMAL .... Vertical resolution 380 lines. | V.MAX |
| |
| • V.MAX | Vertical resolution 450 lines |
|
|
| (The sensitivity is degraded and the bright sections may be colored |
|
| |
| depending on the subject.) |
|
| |
KNEE | Sets the knee point (brightness level) when the AUTO KNEE function is | 80% | 100% | |
POINT | set to OFF. |
| 85% |
|
|
|
| 90% |
|
|
|
| 95% |
|
|
|
| 100% |
|
ADVANCED | Displays the ADVANCED PROCESS Screen. |
|
| |
PROCESS | ☞ See "ADVANCED PROCESS Screen" on page 81. |
|
| |
PAGE BACK | The CAMERA MENU returns when the SHUTTER dial is pressed with | – | – | |
| the cursor at this position. |
|
|
79 | 80 |