9. TIME CODE OPERATION
9. TIME CODE OPERATION
The
2. | HOLD button |
|
| 4. | SHIFT button | |
AUDIO |
|
|
|
| ||
LEVEL |
|
|
|
| ||
|
| |||||
|
|
| ||||
|
|
| AUTO |
| FRONT | |
|
|
| MANUAL |
| REAR | |
|
| AUDIO SELECT |
| AUDIO INPUT | ||
|
| VTR SELECT TC GENE. |
| MENU | ||
SEE |
| INT |
| CONTINUE | ||
INSTR- |
| PRST | REC |
|
| |
UCTION |
| PARA | FREE |
|
| |
MANUAL |
| EXT | REGEN |
|
|
|
LITHIUM BATT. | CAM AUX | GROUP | ITEM | SELECT | DATA SET | |
|
| HOLD | SHIFT | ADVANCE PRESET | ||
|
|
| ||||
|
| VTR INPUT |
|
|
|
|
|
| 3. ADVANCE |
| 6. | ||
|
|
| PRESET | |||
|
|
| button |
| ||
|
|
|
| button | ||
|
|
|
|
|
| |
|
|
|
|
| HOLD | |
|
| H | M | S |
| F |
|
|
|
|
| HOLD | |
|
| H | M | S |
| F |
|
|
|
|
| HOLD | |
|
| H | M | S |
| F |
|
|
|
|
| HOLD | |
|
| H | M | S |
| F |
1. Display the time code on the counter display. Set the COUNTER switch to "TC".
•Time code up to 23 hrs. 59 min. 59 sec. 29 frames can be preset.
2. Place the time code generator in preset mode. Press the HOLD button.
•The "HOLD" indicator lights on the display to indicate the preset mode. The first digit of the counter display blinks.
3. Set the value of the blinking digit. Press the ADVANCE button.
•The value of the blinking digit changes.
4. Change the blinking digit. Press the SHIFT button.
•The blinking digit changes.
5. Set the desired value for all digits. Repeat steps 3. and 4. for each digit.
6. Preset the set data in the memory. Press the PRESET button.
• | The set data is saved as the time code generator value. |
| Following the above operation, the "HOLD" indicator |
| disappears from the display, the counter stops blinking |
| and the time code is preset. |
in time code generator runs even when the external time code input stops. Even when the power is switched off, it continues to run
on the backup lithium battery. |
|
|
|
|
Sync signal generator |
|
|
|
|
|
| PUSH |
|
|
REF Video signal |
|
|
|
|
|
| VTR/RM | DV CAMCORDER |
|
|
|
|
| |
External time code generator |
|
|
|
|
|
|
|
| GENLOCK/AUX IN |
|
| Y/C OUT MONITOR OUT LINE OUT | VIDEO OUT | |
|
|
| REMOTE |
|
|
|
|
| AUDIO IN |
|
|
|
| FRONT |
|
| TC IN | TC OUT | LENS |
LTC time code signal |
|
|
| |
REF Video signal |
|
|
| GENLOCK/AUX |
|
|
|
| IN connector |
1. Input the reference video signal into the external time code | 5. Set and operate the external time code generator. | |||
generator and the GENLOCK/AUX IN connector of this unit. | ➡ | The | ||
Note : |
| input external time code data. |
| |
| The SLAVE indicator lights on the display. | |||
When the power is switched ON while external sync signal |
| |||
|
|
|
| |
is input, the screen moves in a vertical direction for a few |
| SLAVE |
|
|
seconds. This is not a malfunction. |
|
|
| |
|
|
|
|
• If the REC/FREE switch is set to FREE, the time code |
starts to run. |
If you preset a wrong time code, perform steps 2. 3. 4. 5. and |
6. again. |
2. Input the SMPTE standard LTC time code signal into the TC IN connector.
3. Display time code on the counter display.
4. Set the switches in the TC GENERATOR block as follows.
•Set the TC GENE switch to “FREE”.
*While the TC GENE switch is set to “REC” or “REGEN”,
Set the related VCR Setup Menus. |
H | M | S | F |
*If the external time code generator phase is not genlocked with the phase of the camera video signals, the “SLAVE” display will flicker.
•Once slave locking has been made, the
Note : Do not connect or disconnect slaves during recording as this may disturb the servo lock.
PRESETTING USER'S BIT DATA | |||||||||
RESET button |
|
|
|
|
|
|
|
| |
| OPERATE/WARNING |
|
|
|
|
|
|
| |
| CH 1 |
|
| OVER | AUTO OFF DEW | LIGHT | |||
RESET |
|
| ON | ||||||
| 40 30 20 | 10 | 0 dB |
|
|
|
| ||
| CH 2 |
|
| OVER | SERVO RF L i OFF | ||||
| 32k | 48k | SLAVE | PB | NDF | HOLD |
|
| |
MONITOR AUD LOCK SP |
|
|
|
|
| F COUNTER | |||
SELECT MENU | WIDE | H | M |
| S |
| |||
REMAIN |
| REV FWD | E | BATT F |
| CTL | |||
MIX |
|
| TC | ||||||
| H | M |
|
|
|
|
| UB |
•Pressing the RESET button in the preset mode resets the time code or user's bit data to 00 00 00 00.
•If you press the HOLD button by mistake, press the HOLD button once more to return to the previous display.
Display user's bit data on the counter display and perform the same procedure as the time code presetting procedure.
•The user's bit can be specified using numerals or alphabetic letters from 0 to F for each digit.
Note: Do not set “F” to all user’s bit, or the data can not be read.
• | Set the VCR Setup Menu item No. 398 SSF MODE to |
| “OFF”. |
| * If set to CUE mode or MARK mode, the |
| will not take place. |
• | Set the VCR Setup Menu item No. 403 |
| Set to “TC&UB” when the user’s bits should also be slave- |
| locked with the external time code generator. |
• | The framing mode will be the same mode as the |
| automatically entered time code (drop frame of |
| frame). |
| During the |
| light on the display. |
| During the drop frame mode, the DF indicator will light |
| on the display. |
| (U MODEL) |
from the sync signal generator. |
|
MASTER | SLAVE |
TC OUT | TC IN | GENLOCK/ |
|
| AUX IN |
MONITOR OUT
63 | 64 |