9. TIME CODE OPERATION

9-2 Presetting and Recording of Time Code (Cont’d) TIME CODE PRESETTING PROCEDURE

9. TIME CODE OPERATION

9-3Recording Time Codes by Slave-Locking the Built-in Time Code Generator with External TCG

The built-in time code generator can be synchronized (slave-locked) with the SMPTE-standard (U MODEL)/EBU-standard (E MODEL) LTC time code signal which is input through the TC IN connector. Once the slave locking has been carried out, the built-

2.

HOLD button

 

 

4.

SHIFT button

CH-1

AUDIO

CH-2

 

 

 

 

LEVEL

 

 

 

 

 

CH-1

CH-2

 

CH-1

CH-2

 

 

 

 

 

 

AUTO

 

FRONT

 

 

 

MANUAL

 

REAR

 

 

AUDIO SELECT

 

AUDIO INPUT

 

 

VTR SELECT TC GENE.

 

MENU

SEE

 

INT

 

CONTINUE

INSTR-

 

PRST

REC

 

 

UCTION

 

PARA

FREE

 

 

MANUAL

 

EXT

REGEN

 

 

 

LITHIUM BATT.

CAM AUX

GROUP

ITEM

SELECT

DATA SET

 

 

HOLD

SHIFT

ADVANCE PRESET

 

 

 

 

 

VTR INPUT

 

 

 

 

 

 

3. ADVANCE

 

6.

 

 

 

PRESET

 

 

 

button

 

 

 

 

 

button

 

 

 

 

 

 

 

 

 

 

 

HOLD

 

 

H

M

S

 

F

 

 

 

 

 

HOLD

 

 

H

M

S

 

F

 

 

 

 

 

HOLD

 

 

H

M

S

 

F

 

 

 

 

 

HOLD

 

 

H

M

S

 

F

1. Display the time code on the counter display. Set the COUNTER switch to "TC".

Time code up to 23 hrs. 59 min. 59 sec. 29 frames can be preset.

2. Place the time code generator in preset mode. Press the HOLD button.

The "HOLD" indicator lights on the display to indicate the preset mode. The first digit of the counter display blinks.

3. Set the value of the blinking digit. Press the ADVANCE button.

The value of the blinking digit changes.

4. Change the blinking digit. Press the SHIFT button.

The blinking digit changes.

5. Set the desired value for all digits. Repeat steps 3. and 4. for each digit.

6. Preset the set data in the memory. Press the PRESET button.

The set data is saved as the time code generator value.

 

Following the above operation, the "HOLD" indicator

 

disappears from the display, the counter stops blinking

 

and the time code is preset.

in time code generator runs even when the external time code input stops. Even when the power is switched off, it continues to run

on the backup lithium battery.

 

 

 

 

Sync signal generator

 

 

 

 

 

 

PUSH

 

 

REF Video signal

 

 

 

 

 

 

VTR/RM

DV CAMCORDER

 

 

 

 

GY-DV550

 

External time code generator

 

 

 

 

 

 

 

 

GENLOCK/AUX IN

 

 

Y/C OUT MONITOR OUT LINE OUT

VIDEO OUT

 

 

 

REMOTE

 

 

 

 

 

AUDIO IN

 

 

 

 

FRONT

 

 

TC IN

TC OUT

LENS

LTC time code signal

 

 

 

REF Video signal

 

 

 

GENLOCK/AUX

 

 

 

 

IN connector

1. Input the reference video signal into the external time code

5. Set and operate the external time code generator.

generator and the GENLOCK/AUX IN connector of this unit.

The built-in time code generator is slave-locked with the

Note :

 

input external time code data.

 

 

The SLAVE indicator lights on the display.

When the power is switched ON while external sync signal

 

 

 

 

 

is input, the screen moves in a vertical direction for a few

 

SLAVE

 

 

seconds. This is not a malfunction.

 

 

 

 

 

 

 

• If the REC/FREE switch is set to FREE, the time code

starts to run.

 If you preset a wrong time code, perform steps 2. 3. 4. 5. and

6. again.

2. Input the SMPTE standard LTC time code signal into the TC IN connector.

3. Display time code on the counter display.

4. Set the switches in the TC GENERATOR block as follows.

Set the TC GENE switch to “FREE”.

*While the TC GENE switch is set to “REC” or “REGEN”, slave-locking will not take place.

 Set the related VCR Setup Menus.

H

M

S

F

*If the external time code generator phase is not genlocked with the phase of the camera video signals, the “SLAVE” display will flicker.

Once slave locking has been made, the built-in time code generator keeps on running even when the external time code generator is stopped.

Note : Do not connect or disconnect slaves during recording as this may disturb the servo lock.

PRESETTING USER'S BIT DATA

RESET button

 

 

 

 

 

 

 

 

 

OPERATE/WARNING

 

 

 

 

 

 

 

 

CH 1

 

 

OVER

AUTO OFF DEW

LIGHT

RESET

 

 

ON

 

40 30 20

10

0 dB

 

 

 

 

 

CH 2

 

 

OVER

SERVO RF L i OFF

 

32k

48k

SLAVE

PB

NDF

HOLD

 

 

MONITOR AUD LOCK SP

 

 

 

 

 

F COUNTER

SELECT MENU

WIDE

H

M

 

S

 

CH-1

REMAIN

 

REV FWD

E

BATT F

 

CTL

MIX

 

 

TC

CH-2

 

H

M

 

 

 

 

 

UB

Pressing the RESET button in the preset mode resets the time code or user's bit data to 00 00 00 00.

If you press the HOLD button by mistake, press the HOLD button once more to return to the previous display.

Display user's bit data on the counter display and perform the same procedure as the time code presetting procedure.

The user's bit can be specified using numerals or alphabetic letters from 0 to F for each digit.

Note: Do not set “F” to all user’s bit, or the data can not be read.

Set the VCR Setup Menu item No. 398 SSF MODE to

 

“OFF”.

 

* If set to CUE mode or MARK mode, the slave-locking

 

will not take place.

Set the VCR Setup Menu item No. 403 U-BIT SLAVE.

 

Set to “TC&UB” when the user’s bits should also be slave-

 

locked with the external time code generator.

The framing mode will be the same mode as the

 

automatically entered time code (drop frame of non-drop

 

frame).

 

During the non-drop frame mode, the NDF indicator will

 

light on the display.

 

During the drop frame mode, the DF indicator will light

 

on the display.

 

(U MODEL)

Multi-CamcorderMaster-Slave Connection When there is only one slave GY-DV550, connect it as indicated in the figure below. When connecting several GY-DV550s as slaves, input the REF video signal to GENLOCK/AUX IN connectors of all these units

from the sync signal generator.

 

MASTER

SLAVE

GY-DV550

GY-DV550

TC OUT

TC IN

GENLOCK/

 

 

AUX IN

MONITOR OUT

63

64

Page 33