SETTING AND ADJUSTMENTS BEFORE SHOOTING
CAUTION
When the AUDIO INPUT switch is set to MIC, be sure to
check that the microphone is connected to the INPUT1/2
connector. If the microphone is not connected, increasing
the audio level could cause noise from the input connec-
tor to be recorded on the tape. When the microphone is
not connected to the INPUT1/2 connector, set the AUDIO
INPUT switch to “LINE” or turn down the audio level con-
trol.
In the FULL AUTO mode, the audio level volume cannot
be adjusted with the audio level controls on the CH-1 and
CH-2.
MEMO
The reference level for audio recorded on the tape can be
set with the AUDIO REF. LEVEL item on the AUDIO/MIC
menu screen. (–20 dB or –12 dB) The level will change for
both CH-1 and CH-2.
Monitoring Audio during Recording
The audio input during recording, in record-pause or stop
mode can be monitored through the monitoring speaker or
earphone.
Select the audio channel to be monitored using the MONI-
TOR SELECT switch.
The MONITOR volume control adjusts the monitoring vol-
ume.
The loudspeaker or earphone outputs an alarm tone in the
case of an abnormal conditio n occurring in the unit.
An alarm tone is also output when the tape end is reached
or when the battery is running down.
* Do not increase the audio monitoring volume exces-
sively; otherwise howling with the camera microphone
may occur.
MEMO
When connecting a stereotype earphone, make the fol-
lowing settings to output stereo sound.
1Set the MONITOR SELECT switch to BOTH.
2
Set the AUDIO MONITOR item on the AUDIO/MIC [2/2]
menu screen to STEREO.
When AUDIO MONITOR item on the AUDIO/MIC [2/2]
menu screen is set to “STEREO”, only the audio of CH-1
is output from the monitoring speaker.
The volume of the alarm tone is set with the ALARM VR
LEVEL item on the OTHERS [1/2] menu screen. (OFF/
LOW/MIDDLE/HIGH)
PHONES jack
CH-1 : The sound input to the CH-1 channel is output.
BOTH : The sound input to the CH-1 and CH-2 channels
is output mixed.
CH-2 : The sound input to the CH-2 channel is output.