3. Settings and adjustments for recording
Setting the dip switches
The type of PC monitor to use and the ID during SCSI connection are set using the dip switches.
SCSI
REC
SEND AW/SEL MODE
MENU UP DOWN SET
PLAY
FREEZE
MONITOR LENS
MEMO
Turn the power off before setting the dip switches. Setting the switches with the power on will not change the set-
Dip switches
REMOTE | DC IN | tings. |
ON 1 2 3 4 | POWER |
@@ @ @ @SEE INSTRUCTION@MANUAL
Monitor settings
Dip switch no. 3 is set depending on whether the PC monitor being used is a VGA monitor or a SXGA monitor. <Default setting: OFF>
ON 1 2 3 4 | VGA output terminal |
| Set when directly connecting a VGA monitor to the MONITOR ter- |
Set to OFF | minal on the rear of the main unit. |
|
ON 1 2 3 4
Set to ON
SXGA output setting
Set for systems using a SXGA monitor.
The signal from the MONITOR terminal on the rear of the main unit is inputted through the analog input compatible video capture board. ( ☞ Page 65 Compatible systems 2)
SCSI ID settings
Sid switches 1 and 2 are set depending on the used system to set the SCSI ID. <Default ID: 7>
ON 1 | 2 | 3 | 4 | Set when connecting a printer or MO drive directly to the main unit. | |
When making this setting, the main unit will become the host (ini- | |||||
|
|
| ID=7 | ||
ON 1 | 2 | 3 | 4 | tiator). | |
|
ID=6
ON 1 2 3 4
ID=5
ON 1 2 3 4
ID=4
Set when exporting images to a PC.
Make sure that the ID numbers of the connecting devices are not the same.
When making this setting, the PC will become the host (initiator) and the main unit will become the target.
( ☞ Page 64 Connecting to a PC)