GAMMA

Used to set whether the gamma curve to determine the

NORMAL

 

 

reproduction of black is to be set using the standard value

 

 

 

or available for change.

 

 

 

NORMAL: the gamma curve is set using the standard

 

 

 

value (0.45)

 

@ @ @ @ @

@ADJUST: set when changing the gamma curve

 

 

LEVEL

The gamma curve can be adjusted only when GAMMA is

0.45

 

 

set to ADJUST.

 

 

 

Increase the number: improves the reproduction of

 

 

 

black. However, the reproduction

 

 

 

quality of bright areas becomes

 

 

 

lower.

 

 

 

Decrease the number: improves the reproduction of

 

 

 

bright areas. However, the repro-

 

 

 

duction quality of black becomes

 

 

 

lower.

 

 

 

[Variable range: 0.35 ~ 1.00 (21 steps)]

 

 

 

 

 

MASTER BLACK

Used to adjust the pedestal level (master black), which is

0

 

 

the standard black during lens cap. To view black areas,

 

 

 

increase the pedestal level to brighten the entire screen.

 

 

 

Increase the pedestal level: increase the number

 

 

 

Decrease the pedestal level: decrease the number

 

 

 

[Variable range: –99 ~ 99]

 

 

 

 

 