is provided with two additional
to power supply
2-pole connector
Trigger inputs/ switching outputs 4-pole connector
Figure 8 : View of a split cable
to camera D-SUB9-pole
RS-232D-SUB9-pole to PC/IPC

Manual: CMOS Industrial Camera LOGLUX® i5

Version 1.08 (04/07)

⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯

If no difficulties occurred during installation, the CameraLinkMVtitan-CL PC plug-in card is properly installed.

Note: In general, no re-registration with Microsoft®, the maker of the Windows® operating system,

(Microsoft® safety system) will be necessary. Please make sure you use drivers certified by Microsoft® where possible. See also the information of the plug-in card manufacturer.

Installation of the CMOS industrial camera LOGLUX® i5 CL

Once the CameraLink(see above) has been properly installed, the installation of the CMOS industrial camera LOGLUX® i5 CL is very easy.

First mount the CMOS industrial camera LOGLUX® i5 CL in a safe and stable manner. Use the slot on the bottom of the camera housing and the associated keys for the purpose, where possible, as these allow safe fastening to various modular design systems having fitting counterparts.

Once the CMOS industrial camera LOGLUX® i5 CL has been safely mounted, connect the cables to the host system (PC or IPC).

For the purpose, plug the properly laid customized data cables into the

corresponding electrical/mechanical connectors on the camera and into the CameraLinkMVtitan-CL PC plug-in card of the PC or IPC. Then connect the split adapter (Fig. 7) to the 9-pole D- SUB connector on the camera and power supply unit (plug-type or DIN/EN

bus-bar power supply unit). Furthermore, you may use the split adapter to link the camera up with an optional triggering system, e.g. the switching output of a light barrier, in order to trigger the framegrabbing

process in an event-controlled mode. The same plug connector switching outputs.

Once the plug connectors and data cables have been safely connected, the operating voltage (24 V

±10%) can be applied to the camera.

Caution: Always use the plug-type power supply unit supplied with the CMOS industrial camera

LOGLUX® i5 CL SET, or DIN bus-bar type 24V power supply units which are suitable for industrial control systems (PLCs)! Always connect the camera to a separate power supply!

Readiness for operation is indicated by the continuously lit green status LED on the rear of the CMOS industrial camera LOGLUX® i5 CL.

The CMOS industrial camera LOGLUX® i5 CL is now ready for operation. The next step is the installation of the ‚LOGLUX® LuxWare‘ configuration tool.

Installation of the LOGLUX® LuxWare configuration tool

Once the CMOS industrial camera LOGLUX® i5 CL has been properly prepared, the installation of the LOGLUX® LuxWare is very easy.

After booting the PC and logging into the Windows® operating system as administrator, the LOGLUX® LuxWare software is automatically started after insertion of the CD ROM if you have activated the auto CD ROM start option on your computer.

If not, start ‚Setup.exe‘ in the main directory of the CD ROM manually. In both cases, follow the instructions given by the installation software.

KAMERA WERK DRESDEN GmbH

Page 11 of 46