Version 1.08 (04/07)Manual: CMOS Industrial Camera LOGLUX® i5

⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯

Example:

w $14C #1;permanent precharging

PROFILE_DESCRIPTION

The register contains a string of 32 ASCII characters that identify the profile.

Function group ‚Working parameters‘

This function group provides various camera service registers, among them registers specifying the firmware of the camera as well as functions for setting the trigger register, for initializing and copying camera profiles, and for reading a temperature sensor inside the camera. Please note that these registers are volatile, i.e. the register values are not saved when the power is turned off.

Register

 

Address

Format

Description

 

Value range

Meaning

Access

PARAM_VERSION

 

$900

1 long

Firmware version

 

 

 

read only

PARAM_EVENT

 

$904

1 byte

Event generation for trigger

 

Write access releases a trigger

 

 

 

 

 

and switchport

 

$01

signal, switchport 1 event or

write

 

 

 

 

 

 

$02

switchport 2 event

only

 

 

 

 

 

 

$04

 

 

PARAM_INITPROFILE

 

$905

1 byte

Initializes a profile

 

$1x ... 4x

Initializes profile 1 ... 4 with the

write

 

 

 

 

 

 

 

Init values for

only

 

 

 

 

 

 

$x1

Single integration slope mode

 

 

 

 

 

 

 

$x2

Dual integration slope mode

 

 

 

 

 

 

 

$x3

Quadr. integration slope mode

 

PARAM_COPYPROFIL

 

$906

1 byte

Copies a profile

 

$1x ... $8x

Target profile 1 ... 4

write

 

 

 

 

 

 

$x1 ... $x8

Source profile 1 ... 4

only

PARAM_TEMP0

 

$908

1 word

Temperature sensor 0

 

218 .. 398

Temperature in [Kelvin]

read only

PARAM_TEMP1

 

$90A

1 word

Temperature sensor 1

 

218 .. 398

Temperature in [Kelvin]

read only

Table 6 : Registers of function group 'Working parameters'

 

 

 

 

PARAM_VERSION

This register allows the camera to be identified from the host register.

 

PARAM_EVENT

Events can be generated in the camera by entering data in this register.

 

 

These events are sent to various modules such as the trigger or switchport

 

 

module. Functions can be triggered in the respective module if the event

 

 

register had been specified in the module's event source parameter. Example:

 

 

If

the value $04 (event

register) had been entered in

register

PROFILE_TRGSOURCE, a write access to register PARAM_EVENT using the value $01 will trigger a framegrabbing process. This could be done to simulate the response of the camera to an external trigger signal.

PARAM_INITPROFILE

The register permits the factory (default) settings of camera profiles 1 to 4 to be reset. The register content of the respective target profile will be irrevocably overwritten by the register content of the source profile.

Example:

w $905$13;initializes P1 with P3

PARAM_COPYPROFILE

The register permits camera profiles 1 to 8 to be given identical register contents. The register content of the respective target profile will be irrevocably overwritten by the register content of the source profile.

Example:

w $906$62;copies Profil2 to Profil6

Page 36 of 46

KAMERA WERK DRESDEN GmbH